York ZJ R-410A User Manual

Page 22

Advertising
background image

251934-YTG-G-0708

22

Johnson Controls Unitary Products

115°F

125°F

3750

77

180.3

17.1

78.5

67.6

49.8

-

-

-

166.8

18.9

68.4

61.1

43.5

-

-

-

72

167.2

16.9

111.3

93.5

75.7

57.9

-

-

154.4

18.7

105.1

87.6

70.0

52.4

-

-

67

154.0

16.8

144.1 119.5 101.7

83.9

66.1

-

141.9

18.6

141.9 114.0

96.5

78.9

61.3

-

62

143.0

16.6

143.0 143.0 124.7 106.9

89.1

71.3

131.7

18.4

131.7 131.7 120.0 100.6

83.0

65.5

4500

77

186.6

17.0

95.7

75.3

54.8

-

-

-

172.7

18.8

89.1

68.5

48.1

-

-

-

72

173.0

16.8

124.3 103.8

83.4

62.9

-

-

159.8

18.6

118.0

97.7

77.3

57.0

-

-

67

159.5

16.7

152.9 132.4 111.9

91.5

71.0

-

146.9

18.4

146.9 126.9 106.6

86.2

65.9

-

62

148.0

16.5

148.0 148.0 137.3 116.8

96.4

75.9

136.4

18.3

136.4 136.4 130.6 110.2

89.9

69.6

57

149.2

16.6

149.2 149.2 132.8 112.4

91.9

71.5

139.1

18.4

139.1 139.1 123.0 102.7

82.3

62.0

5250

77

193.0

16.8

113.0

83.0

59.8

-

-

-

178.6

18.6

109.8

75.8

52.7

-

-

-

72

178.9

16.7

137.3 114.2

91.0

67.9

-

-

165.3

18.4

130.9 107.8

84.7

61.6

-

-

67

164.9

16.5

161.6 145.3 122.2

99.1

76.0

-

152.0

18.3

152.0 139.8 116.7

93.6

70.5

-

62

153.1

16.4

153.1 153.1 149.9 126.8 103.7

80.5

141.1

18.1

141.1 141.1 141.1 119.9

96.8

73.7

57

154.2

16.5

154.2 154.2 145.0 121.9

98.8

75.6

143.8

18.2

143.8 143.8 134.7 111.6

88.5

65.4

6000

77

199.3

16.7

130.3

90.7

64.9

-

-

-

184.5

18.5

130.5

83.2

57.3

-

-

-

72

184.8

16.6

150.3 124.5

98.7

72.9

-

-

170.8

18.3

143.7 117.9

92.0

66.2

-

-

67

170.3

16.4

170.3 158.3 132.5 106.7

80.9

-

157.0

18.1

157.0 152.6 126.8 100.9

75.1

-

62

158.1

16.3

158.1 158.1 162.5 136.7 110.9

85.1

145.8

18.0

145.8 145.8 145.8 129.5 103.6

77.8

57

159.3

16.3

159.3 159.3 157.2 131.4 105.6

79.8

148.6

18.1

148.6 148.6 146.4 120.5

94.7

68.8

6600

72

186.1

16.6

158.7 131.5 104.3

77.0

-

-

171.7

18.3

152.1 124.8

97.5

70.2

-

-

67

171.5

16.4

171.5 165.5 140.0 112.7

85.5

-

157.9

18.1

157.9 157.9 134.2 106.9

79.7

-

62

159.2

16.3

159.2 159.2 161.4 134.2 106.9

79.7

146.6

18.0

146.6 146.6 146.6 124.1

96.8

69.5

57

160.4

16.4

160.4 160.4 159.4 132.1 104.9

77.7

149.4

18.1

149.4 149.4 148.3 121.1

93.8

66.5

7200

72

187.3

16.6

167.1 138.5 109.8

81.2

-

-

172.7

18.3

160.4 131.6 102.9

74.2

-

-

67

172.6

16.4

172.6 172.6 147.4 118.8

90.1

-

158.8

18.2

158.8 158.8 141.7 113.0

84.2

-

62

160.3

16.3

160.3 160.3 160.3 131.6 102.9

74.3

147.4

18.0

147.4 147.4 147.4 118.7

90.0

61.2

57

161.5

16.4

161.5 161.5 161.5 132.8 104.2

75.5

150.3

18.1

150.3 150.3 150.3 121.6

92.8

64.1

1. These capacities are gross ratings. For net capacity, deduct air blower motor, MBh = 3.415 x kW. Refer to the appropriate Blower

Performance Table for the kW of the supply air blower motor.

2. These ratings include the condenser fan motors (total 1 kW) and the compressor motors but not the supply air blower motor.

ZJ180 (15 Ton) (Continued)

Air on

Evaporator Coil

Temperature of Air on Condenser Coil

Total

Capacity

1

(MBh)

Total
Input

(kW)

2

Sensible Capacity (MBh)

Total

Capacity

1

(MBh)

Total
Input

(kW)

2

Sensible Capacity (MBh)

CFM

WB
(°F)

Return Dry Bulb (°F)

Return Dry Bulb (°F)

90

85

80

75

70

65

90

85

80

75

70

65

Advertising