York ZJ R-410A User Manual

Page 52

Advertising
background image

251934-YTG-G-0708

52

Johnson Controls Unitary Products

ZJ180-300 Bottom Duct Application

ZJ180 (15 Ton) Bottom Duct

Air Flow

(CFM)

Available External Static Pressure - IWG

1

1. Blower performance includes gas heat exchangers and 2” filters. See STATIC RESISTANCE table for additional applications.
2. See RPM SELECTION table to determine desired motor sheave setting and to determine the maximum continuous BHP.
3. kW = BHP x 0.898.

0.4

0.6

0.8

1.0

1.2

1.4

1.6

1.8

2.0

2.2

2.4

2.6

RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP

Standard 5 HP &

Field Supplied Drive

Standard 5 HP & Drive

High Static 5 HP & Drive

4000

768 1.24 806 1.55 846 1.83 888 2.09 930 2.32 972 2.53 1015 2.73 1056 2.91 1097 3.09 1136 3.27 1173 3.44 1208 3.61

4400

797 1.65 835 1.96 875 2.24 916 2.49 959 2.72 1001 2.93 1043 3.13 1085 3.32 1126 3.50 1165 3.67 1202 3.84 1237 4.02

4800

828 2.09 866 2.40 906 2.68 947 2.93 989 3.16 1032 3.38 1074 3.58 1116 3.76 1157 3.94 1196 4.11 1233 4.28 1267 4.46

5200

860 2.57 898 2.88 938 3.16 980 3.41 1022 3.65 1064 3.86 1107 4.06 1148 4.24 1189 4.42 1228 4.59 1265 4.77 1300 4.94

5600

894 3.09 932 3.40 972 3.68 1014 3.93 1056 4.16 1098 4.38 1141 4.57 1182 4.76 1223 4.94 1262 5.11 1299 5.28 1334 5.46

6000

930 3.64 968 3.95 1008 4.23 1049 4.48 1091 4.71 1134 4.93 1176 5.12 1218 5.31 1259 5.49 1298 5.66

-

-

-

-

6400

966 4.22 1005 4.53 1045 4.81 1086 5.06 1128 5.30 1171 5.51 1213 5.71

-

-

-

-

-

-

-

-

-

-

6800

1005 4.84 1043 5.14 1083 5.42 1124 5.68

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

7200

1044 5.48

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

5 HP & Field Supplied Drive

ZJ210 (17.5 Ton) Bottom Duct

Air Flow

(CFM)

Available External Static Pressure - IWG

1

1. Blower performance includes gas heat exchangers and 2” filters. See STATIC RESISTANCE table for additional applications.
2. See RPM SELECTION table to determine desired motor sheave setting and to determine the maximum continuous BHP.
3. kW = BHP x 0.838.

0.4

0.6

0.8

1.0

1.2

1.4

1.6

1.8

2.0

2.2

2.4

2.6

RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP

Standard 5 HP &

Field Supplied Drive

Standard 5 HP & Drive

High Static 7.5 HP & Drive

4400

661 0.74 697 1.19 733 1.62 768 2.03 803 2.40 838 2.73 871 3.02 904 3.26 935 3.45 964 3.59 992 3.66 1018 3.67

4800

677 1.07 712 1.53 748 1.96 784 2.36 819 2.73 853 3.06 887 3.35 919 3.59 950 3.79 980 3.92 1008 4.00 1034 4.01

5200

694 1.43 730 1.89 766 2.32 801 2.72 836 3.09 871 3.42 904 3.71 937 3.95 968 4.14 997 4.28 1025 4.35 1051 4.37

5600

713 1.82 749 2.27 785 2.71 820 3.11 856 3.48 890 3.81 923 4.10 956 4.34 987 4.53 1017 4.67 1045 4.74 1071 4.75

6000

734 2.25 770 2.70 806 3.13 841 3.53 877 3.90 911 4.23 944 4.52 977 4.77 1008 4.96 1038 5.09 1066 5.17 1092 5.18

6400

757 2.71 793 3.17 829 3.60 864 4.00 899 4.37 934 4.70 967 4.99 1000 5.23 1031 5.42 1060 5.56 1088 5.64 1114 5.65

6800

781 3.22 817 3.68 853 4.11 888 4.51 923 4.88 958 5.21 991 5.50 1024 5.74 1055 5.94 1085 6.07 1112 6.15 1139 6.16

7200

807 3.78 843 4.23 878 4.66 914 5.07 949 5.44 983 5.77 1017 6.06 1049 6.30 1081 6.49 1110 6.63 1138 6.70 1164 6.71

7600

834 4.38 870 4.83 905 5.26 941 5.67 976 6.04 1010 6.37 1044 6.66 1076 6.90 1108 7.09 1137 7.23 1165 7.30 1191 7.31

8000

862 5.02 898 5.48 934 5.91 969 6.31 1004 6.68 1039 7.01 1072 7.30 1105 7.55 1136 7.74 1166 7.87 1194 7.95 1220 7.96

8400

892 5.71 928 6.17 963 6.60 999 7.00 1034 7.37 1069 7.70 1102 7.99 1134 8.24 1166 8.43 1195 8.56

-

-

-

-

8800

923 6.45 959 6.91 994 7.34 1030 7.74 1065 8.11 1099 8.44

-

-

-

-

-

-

-

-

-

-

-

-

7.5 HP & Field Supplied Drive

Advertising