Table b.11, Protection commands, Table b.12 – Xantrex Technology GPIB-M-XT User Manual

Page 114: User lines, Table b.13, Output state, Scpi command reference scpi command summary

Advertising
background image

112

Operating Manual for Multichannel Functionality (GPIB-M)

SCPI Command Reference
SCPI Command Summary

Ta

b

le

B

.1

1

Pr

otection Com

m

an

ds

Ta

ble B.12

User

L

ines

Ta

ble B.13

Output

S

tate

Quer

y t

he S

tandar

d Event

regist

er (ES

R

?)

[:]ST

ATus[<cha

nnel>]:ST

ANdard[:E

VENt]?

S

ee

Table 4.

10,

on p

age 78

.N

/A

Enab

le the

S

ta

ndar

d

Event

r

egist

er

(*E

SE,

*ESE

?)

[:]ST

ATus[<cha

nnel>]:ST

ANdard:EN

ABle

S

ee

Table 4.

10,

on p

age 78

.Y

e

s

Quer

y t

he S

tat

us

B

yt

e

(*S

T

B)

[:]ST

ATus[<cha

nnel>]:SB

YTe[:EVEN

t]?

S

ee

Table

4.

11

, o

n

p

a

ge

79

.N

/A

Service Reque

st

Enab

le

(*S

R

E,

*S

R

E

?)

[:]ST

ATus[<cha

nnel>]:SR

EQuest:EN

ABle <sta

tus-enabl

e>

S

e

t

the bit

s in t

he Service Requ

est Ena

b

le

Regist

er

.

Ye

s

F

unction

SCPI Command

De

scr

ipti

on

Quer

y

Set

O

ve

r

Te

m

perat

ure

R

esp

onse

[:]SE

NSe[<chan

nel>]:TEM

Perature:

PROTectio

n:LATCh

<on-o

ff-state>

S

e

lect

if

out

put

is lat

ched

of

f

or

a

u

to

re

co

ve

rs

in

th

e ca

se

o

f an

ov

er

te

m

p

er

a

tu

re

con

d

ition

Ye

s

Quer

y Over

T

e

mpe

rat

ure

Prot

ect

ion T

ripp

e

d

[:]SE

NSe[<chan

nel>]:TEM

Perature:

PROTectio

n:TRIPped

?

Q

uer

y t

e

mpera

tur

e prot

ecti

on tr

ipped

N/A

Set A

C

Fail

Respon

se

[:]SE

NSe[<chan

nel>]:VOL

Tage:AC:P

ROTection

:LATCh

<on-o

ff-state>

S

e

lect

if

out

put

is lat

ched

of

f

or

a

u

to

re

covers i

n

the ca

se

of an AC Fail

Ye

s

Quer

y AC Fail Pro

tect

ion

Tr

ip

pe

d

[:]SE

NSe[<chan

nel>]:VOL

Tage:AC:P

ROTection

:TRIPped?

Q

uer

y AC prot

ect

ion circuit

t

rip

ped

N/A

F

unction

SCPI Command

De

scr

ipti

on

Quer

y

Select p

o

larity o

f Auxilia

ry

Lines

[:]OU

TPut[<cha

nnel>]:AU

Xiliary<A

|B>:POLar

ity

{HIGH

|LOW}

Co

nfi

gure

t

he pola

rit

y of

the

au

xi

liary line

Y

es

Select

S

ource of Auxilia

ry

Line S

tat

e

[:]OU

TPut[<cha

nnel>]:AU

Xiliary<A

|B>:SOURc

e

<aux_

line_mnem

onic>

Co

nfi

gure

the

auxilia

ry li

ne

Y

e

s

Quer

y st

at

e of

Au

xi

liary

Line

[:]OU

TPut[<cha

nnel>]:AU

Xiliary<A

|B>:STATe

?

Quer

y the s

tate

o

f th

e auxiliar

y lin

e

N

/A

F

unction

SCPI Command

De

scr

ipti

on

Quer

y

S

e

t Ou

tp

u

t S

tat

e

[:]OU

TPut[<cha

nnel>][:S

TATe] <on

-

off-stat

e>

E

nabl

e/d

isable t

he power

supp

ly

ou

tp

ut.

Y

es

S

e

t Ou

tp

u

t S

tat

e a

t

Power-

On

[:]OU

TPut[<cha

nnel>]:PO

N:STATe <

o

n-off-st

ate>

S

e

lect

s

th

e st

at

e of

th

e o

u

tp

ut

at

power-

o

n

Y

es

Power-

On Conf

igur

at

ion

[:]OU

TPut[<cha

nnel>]:PO

N:RECall

{PRES

et|USER<s

etting_lo

cation>|S

EQ<sequen

ce_number

>}

Co

nfi

gure

t

he supply to

r

e

call last set

tin

g,

one of

t

he user set

tin

gs, fa

ct

or

y pre

se

t

val

ues

or

to ena

ble an aut

o seque

nce.

Ye

s

Advertising
This manual is related to the following products: