Expressions, Table b.15 – Xantrex Technology GPIB-M-XT User Manual

Page 117

Advertising
background image

SCPI Command Reference

Expressions

Release 2.1

115

Expressions

Ta

b

le

B

.1

5E

xpressions

Expression

De

ta

ils

aux_line_mnemonic

D

ef

in

e the output of the auxiliary line.The p

os

sible values are

N

O

NE, ON

, OFF

, OVOLt

age,

UVOLt

age,

OCURrent,

UCURrent,

ACOFf,

OTEMper

ature, SPRotection, UNRegulated, FOLD, CC,

CV

, CP

.

channel

The address

for a multichannel slave. An integ

er value in the range

2 to 50.

codeword

A

string representing any 4-digit positive integer

.

current

A numeric value as defined by SCPI. May also be

MAXimum

or

MINimum.

May

include

current-related suf

fix unit

s such as “mA”, “uA”,

“A” etc. Ra

nge may be 0 to 103% of model’

s rated

current.

delay

A length of time in the range 0 to 60

s

econd

s.

May include

time-related

su

ffix unit

s such as “S”,

“MIN”, “mS”, “uS” etc. By

d

efault, the value is in seconds.

ESE-word

Ra

nge 0–255. An

8-bit st

atus mask for the S

tandar

d Event S

ta

tus Register that determines which

bit

s are OR’d to form the ESB bit in the S

tatus Byte Register

.

GPIB_address

T

he address

for a GPIB controlled uni

t. An integer value in the range 1 to 30.

on-of

f-st

ate

A

Boolean indicator of a st

ate.

Possible values are

ON

, OFF

, 0

(of

f)

, or

1 (on).

OVP_level

A

numeric value as defined by SCPI. May also be

MAXimum

or

MINimum.

May

include

volt

age-rela

ted s

uf

fix unit

s such as “mV”, “uV”, “V”, etc. Range is

0 to 103% of model’

s rated volt

age.

setting_location

A

numeric indic

ation

of an internal set of

setting re

gisters. An integer value in the range 1 to 10

.

sequence_count

Nu

mber of times a sequ

ence is to b

e repeated. Range is 1 to 9999.

sequence_number

The name

of an auto sequence prog

ram. Range is 1 to 10. The suf

fix is p

art of the SEQUENCE

command name and is not a p

ara

meter

.

st

atus-enable

A

16-bit st

atus mask for any condition regi

st

er that determines wh

ich bit

s a

re to be used for

synthesizing the

su

mmary bit of that register

.

step_number

The step number of an auto sequen

ce

p

rogram. Possibly consid

ered a SCPI suf

fix. Range

is 1 to

99.

step_time

T

he duration of an auto sequence step in the format hh:mm:ss

.s.

May include time-related suf

fix unit

s

su

ch as “S”, “MIN”, “mS”, “uS”, etc. By de

fault, the value is

in

seconds.

volt

age

A numeric value as defined by SCPI. May also be

MAXimum

or

MINimum.

May

include

volt

age-rela

ted s

uf

fix unit

s such as “mV”, “uV”, “V”, etc. Range is

0 to 103% of model’

s rated volt

age.

Advertising
This manual is related to the following products: