background image

Features and Specifications
Specifications

20

Operating Manual for Multichannel Functionality (GPIB-M)

Table 1.2 Specifications for XFR 1200 W with GPIB-M or CANbus

Models

7.5-140

12-100

20-60

35-35

40-30

Program Resolution

Voltage
Current

1.16mV
19.6mA

1.8mV
14mA

3.08mV
8.4mA

5.4mV
5.4mA

6.2mV
4.2mA

Program Accuracy

1

Voltage

Current

10mV
±0.12%
500mA
±0.1%

50mV
±0.12%
460mA
±0.1%

75mV
±0.12%
250mA
±0.1%

75mV
±0.3%
200mA
±0.1%

75mV
±0.3%
150mA
±0.15%

Readback Resolution

Voltage
Current

1.16mV
19.6mA

1.8mV
14mA

3.08mV
8.4mA

5.4mV
5.4mA

6.2mV
4.2mA

Readback Accuracy

1

Voltage

Current

30mV
±0.12%
500mA
±0.1%

60mV
±0.12%
460mA
±0.1%

75mV
±0.12%
250mA
±0.1%

75mV
±0.3%
200mA
±0.1%

75mV
±0.3%
150mA
±0.15%

Models

60-20

100-12

150-8

300-4

600-2

Program Resolution

Voltage
Current

9.2mV
2.8mA

15.4mV
1.68mA

23.1mV
1.12mA

46.2mV
0.56mA

92.4mV
0.28mA

Program Accuracy

1

Voltage

Current

1. Apply accuracy specifications according to the following voltage program accuracy example:

Set a model XFR 20-60 power supply to 10 volts.
The expected result will be within the range of 10 volts ± 75mV ± 0.12% of the set voltage of 10 volts.

150mV
±0.25%
120mA
±0.1%

150mV
±0.35%
80mA
±0.1%

225mV
±0.35%
80mA
±0.1%

225mV
±0.35%
80mA
±0.1%

250mV
±0.35%
50mA
±0.1%

Readback Resolution

Voltage
Current

9.2mV
2.8mA

15.4mV
1.68mA

23.1mV
1.12mA

46.2mV
0.56mA

92.4mV
0.28mA

Readback Accuracy

1

Voltage

Current

150mV
±0.25%
120mA
±0.1%

150mV
±0.35%
80mA
±0.1%

225mV
±0.35%
80mA
±0.1%

225mV
±0.35%
80mA
±0.1%

250mV
±0.35%
50mA
±0.1%