Operation
Power Supply Operation

58

Operating Manual for Multichannel Functionality (GPIB-M)

Read Error

Messages

The error queue holds up to 50 error messages. Once each message has been read, it
is cleared from the system.

To read from the error queue:
SYST:ERR?

This command returns an error code and message from the error queue. For example:

-315, “Configuration memory test”

-100, “Command error”

0, “No error”

See

Appendix C. “Error Messages”

for descriptions of the messages.

Clear Status Issue a Clear Status command to clear all error messages and status registers.

*CLS

or

STATus<channel>:CLEar

Configure

Auxiliary

Status Lines

The Auxiliary (Aux) lines are 2 open collector outputs that can be used to monitor
the status of the power supply. The auxiliary lines are referred to as AUX A and AUX
B. The auxiliary status lines can be set up to report the following status conditions:

NONE

ON: Output On

OFF: Output Off

OVOLtage: Over-Voltage Condition

UVOLtage: Under-Voltage Condition

OCURrent: Over-Current Condition

UCURrent: Under-Current Condition

FOLD: Fold Protection Tripped

CC: Constant Current Mode

CV: Constant Voltage Mode

UNRegulated: Output Unregulated

OTEMperature: Over Temperature Protection Tripper

ACOFf: AC Protection Tripped

SPRotection: Sense Protection Tripper