Operation

Auto Sequencing

Release 2.1

63

Querying the number of steps

To query the number of steps that have been programmed:

PROGram:STEP:COUNt?

Deleting a

Sequence

Deleting Sequences

If you no longer need a sequence, select it with the PROG:NAME command and then
delete it with the following:

PROGram:DELete

You can also use the following to delete all sequences:
PROGram:DELete:ALL

Using Auto

Sequencing

Auto Sequence programs can be set to run as a Power ON default or recalled from
memory.

Auto sequence programs can operate 3 different ways:

They can run automatically through a series of steps, repeating those steps a

pre-set number of times if necessary, and complete their operation without

intervention from an operator.

They can run automatically and be paused. If you need to stop the program

temporarily, change its state to “PAUSE” to stop it, and then change the

program’s state to “RUN” to resume the program’s operation when ready. The

output remains on and voltage may be present at the output.

They can run automatically programmed to wait for a trigger at certain points in

the sequence. If you want the program to resume, you can supply a trigger signal

to the rear panel Trigger input.

Select Sequence to Run

To run an auto sequence program, first select the program you wish to run:

PROGram:NAME <sequence_number>

where <sequence_number>

can range from 1 to 10.