Data Ports

Serial Port

RS-422/RS-485 Interconnections

An interface adapter (Zebra part number 33114M) is required to connect the printer’s RS-232
DB-9 interface to a host computer through an RS-422 or RS-485 interface. A generic DB-25
adapter can be used.

Figure 38

shows the cable wiring for interconnecting the DB-9 to the

interface adapter’s DB-25 female connector.

Figure 38 • DB-9 to DB-25 Connections

Caution • A qualified service technician must install a jumper on the printer’s main logic
board at JP1, pins 2 and 3, for the RS-422/RS-485 interface adapter to function properly.

Female DB-25 Connector on

RS-422/RS-485 Adapter

Data input B (–)

Data input A (+)

Data output B (–)

Data output A (+)

Frame ground

Signal ground ref.

+5 VDC 725 mA source

1

9

11

13

14

16

19

NOTE: Pins 2–8, 10, 12, 15, 17, 18, and 20–25 are unused and unterminated.