Specify rfid retries for a block – Zebra Technologies R170XiTM User Manual

Page 98

Advertising
background image

86

R110Xi/R170Xi User Guide

12/23/04 23063L-003 Rev. 2

RFID Guidelines

^RR

^RR

Specify RFID Retries for a Block

Description This command changes the number of times that the printer attempts to read or
write to a particular block of a single RFID tag. By default, the printer will attempt six retries.
This command is persistent and will be used in subsequent formats if not provided.

Format

^RRn

The following table identifies the parameters for this format.

Important •

This command is not the same as the number of labels to try parameter in the

^RS

command.

Parameters

Details

n

= number of retries

Accepted values: 0 to 10
Default value: 0

Examples •

Set read block retries to 5

^XA

^FN1^RR5^RFR,H^FS

^HV1^FS

^XZ

Set write block retries to 2

^XA

^RR2^RFW,H^FD1234^FS

^XZ