Read or write rfid format – Zebra Technologies R170XiTM User Manual

Page 95

Advertising
background image

RFID Guidelines

^RF

23063L-003 Rev. 2 12/23/04

R110Xi/R170Xi User Guide

83

^RF

Read or Write RFID Format

Description This command allows you to read or write to an RFID tag.

Format

^RFo,t,b,n

The following table identifies the parameters for this format.

Note •

To read into a field variable, you must have a ^FN command in the

Parameters

Details

o

= operation

The action to be performed.
Accepted values:
• W = write to the tag
• L = write with LOCK (if supported by tag type)
• R = read the tag
Default value: W

t

= type

Accepted values:
• A = ASCII
• H = Hexadecimal
• E = EPC (ensure proper setup with the

^RB

command)

Default value: H

b

= starting block number Accepted values: 0 to n, where n is the maximum number of blocks for the tag.

Default value: 0

n

= number of blocks

to read*

This parameter is valid only for the read operation.
Accepted values: 1 to n, where n is the maximum number of blocks for the tag
type minus the starting block number. For example, if the tag has 8 blocks
(starting with block 0) and you start with block 6, n can be 2. This would return
block 6 and block 7 information.
Default value: 1

*Not applicable for R110Xi/R170Xi