Communications diagnostics test, Additional printer diagnostics – Zebra Technologies R170XiTM User Manual

Page 150

Advertising
background image

138

R110Xi/R170Xi User Guide

23063L-003 Rev. 2 12/23/04

Troubleshooting

Printer Diagnostics

FEED and PAUSE Self Test

Performing this self test temporarily resets the printer configuration to the factory default
values. These values are active only until power is turned off unless you save them
permanently in memory.

To perform a FEED and PAUSE self test, complete these steps:

1.

Turn Off (O) the printer.

2.

Press and hold FEED and PAUSE

while turning the power On (I). Hold FEED and

PAUSE until the DATA light turns off.
No labels print at the end of this test.

Communications Diagnostics Test

This test is controlled from the front panel display. See

Setting Communications Mode

on page 52

.

Figure 53

shows a typical printout from this test. Turn off the power to exit this

self test and return to normal operation.

Figure 53 • Communications Diagnostics Test Label

Additional Printer Diagnostics

Additional diagnostic tests are available for this printer. See the Maintenance Manual for
information about these additional tests.

Note •

The communications test label prints upside-down.

Advertising
This manual is related to the following products: