Communications diagnostics test – Zebra 105SL User Manual

Page 147

Advertising
background image

139

Troubleshooting

Printer Diagnostics

6/30/06

105SL User Guide

11342L-001 Rev. A

Communications Diagnostics Test

The communication diagnostics test is a troubleshooting tool for checking the interconnection
between the printer and the host computer.

When the printer is in diagnostics mode, it prints all data received from the host computer as
straight ASCII characters with the hex values below the ASCII text. The printer prints all
characters received, including control codes such as CR (carriage return).

Figure 38

shows a

typical test label from this test.

Figure 38 • Communications Diagnostics Test Label

To use communications diagnostics mode, complete these steps:

1.

Set the print width equal to or less than the label width being used for the test. See

Set

Print Width on page 82

for more information.

2.

Set the printer to

DIAGNOSTICS. For instructions, see

Set Communications Mode

on page 91

.

The printer enters diagnostics mode and prints any data received from the host computer
on a test label.

3.

Check the test label for error codes. For any errors, check that your communication
parameters are correct.

Errors show on the test label as follows:

FE indicates a framing error.

OE indicates an overrun error.

PE indicates a parity error.

NE indicates noise.

4.

Turn the printer off (

O

) and then back on (

I

) to exit this self test and return to normal

operation.

Note •

The test label prints upside-down.

Advertising