ACCESSORIES

Refer to Price Manual for specific model numbers.

Start Assist Kit (2SA067*)

Blower Time Delay - Available to increase efficiency when
installed. Installs on indoor section and maintains blower for
approximately one minute after cooling thermostat has been
satisfied.

Hard Start Kits - Provides required starting torque for use
with Thermal Expansion Valve Kit.

Low Temperature Cutout (2LT06700224) - Prevents heat
pump operation below -1

0°F ambient temperature.

Compressor Blanket - Designed to further reduce the nor-
mal operating sound.

Add-on Fossil Fuel Control - Interface controls for use with
gas, oil furnaces and the heat pump system are available.

Thermal Expansion Valve Kit - 1TVM700 Series TXV kit
used to improve system performance.

Outdoor Thermostat (2TD06700124) - Provides additional
staging of supplemental electric heat.

Room Thermostats - A wide selection of matching thermo-
stats is available to provide features required for any installa-
tion.

2H/1C, manual changeover electronic non-programmable
thermostat.

3H/2C, non-programmable digital thermostat.

3H/2C, auto/manual changeover, electronic programmable,
7-day, hardwire thermostat.

* For the most current accessory information, refer to the
price book or consult factory.

SOUND POWER RATINGS

* Rated in accordance with ARI 270-95 Standards.

INSTALLATION CLEARANCES

TYPICAL FIELD WIRING

UNIT MODEL

(dBA)*

Cooling

Heating

018

73

72

024

75

76

030

74

76

036

76

77

042

77

78

048

78

78

060

79

79

MINIMUM 18” SERVICE ACCESS
CLEARANCE ON ONE SIDE

60” OVERHEAD
CLEARANCE

10” CLEARANCE
COIL AREA

WEATHERPROOF
DISCONNECT
SWITCH

THERMOSTAT

TO FURNACE OR
AIR HANDLER
TERMINAL BLOCK

NEC CLASS 1 WIRING

NEC CLASS 2 WIRING

TO INDOOR COIL

SEAL OPENING(S) WITH
PERMAGUM OR EQUIVALENT

CONTROL ACCESS PANEL

NOTE: ALL OUTDOOR WIRING

MUST BE WEATHERPROOF.

THERMOSTAT

INDOOR UNIT

DEFROST
CONTROL

1

FIELD

INSTALLED
JUMPER

DEHUMIDIFICATION CONTROL CONNECTION
(Humidistat* Jumper must be removed)

GND.

SCREW

CONTACTOR

T2

T1

L2

L1

M

R

L or X

Y

O

W

G

T

2

E

2

R

R

Y

Y

O

O

W2

W

W1

C

C

X/L

G

W1

BK

GND.

LUG

CIRCUIT

BREAKER***

POWER WIRING

24V CONTROL WIRING
(NEC CLASS 2)

JUMPER TERMINALS E AND W TOHEAT
ON FIRST STAGE DURING EMERGENCY HEAT.

TERMINAL NOT USED ON ALL THERMOSTATS.

POWER WIRING

208/230-1-60

230-1-50

3

CHECK THE LOW VOLTAGE TERMINAL BLOCK ON THE INDOOR UNIT FOR THE ACTUAL ARRANGEMENT OF THE TERMINALS.

4

CONNECT POWER WIRING TO TERMINAL BLOCK 3TB ON UNITS WITHOUT ELECTRIC HEAT OR CIRCUIT BREAKER.

B or C

ALL FIELD WIRING TO BE IN ACCORDANCE WITH ELECTRIC CODE (NEC) AND/OR LOCAL CODES

RED

BLK

YEL

ORG

BRN

PUR

WHT

CC

GRY

/66

5

GRAY FOR USE WITH OPTIONAL OUTDOOR THERMOSTAT KITS.

5