Unitary Products Group

Multipliers for determining the performance with other indoor sections.

*

= Single-phase outdoor units only.

*

= Single-phase outdoor units only.

HEATING PERFORMANCE DATA

CONDENSING UNIT MODEL NO

EABD-F036S, EABD-(T,W)036S**

EVAPORATOR COIL MODEL NO

FC/MC/PC/UC48

AIR TEMP.

ENTERING

OUTDOOR UNIT

AIR TEMP.

ENTERING

INDOOR COIL

ID CFM

1000

1200

1400

MBTUH

KW

C.O.P.

MBTUH

KW

C.O.P.

MBTUH

KW

C.O.P.

60

60

41.6

2.4

5.0

42.2

2.3

5.3

42.7

2.2

5.6

70

40.1

2.6

4.5

40.8

2.5

4.8

41.5

2.4

5.1

80

38.6

2.8

4.1

39.5

2.7

4.3

40.4

2.6

4.6

47

60

35.3

2.3

4.6

35.5

2.2

4.8

35.7

2.1

4.9

70

33.8

2.4

4.2

34.3

2.3

4.3

34.8

2.3

4.5

80

32.4

2.5

3.7

33.1

2.5

3.9

33.8

2.4

4.1

40

60

31.4

2.2

4.2

31.4

2.1

4.4

31.5

2.0

4.5

70

30.2

2.3

3.9

30.6

2.2

4.0

31.0

2.2

4.2

80

29.1

2.4

3.5

29.8

2.4

3.7

30.4

2.3

3.8

30

60

27.4

2.0

3.9

27.3

2.0

4.0

27.3

2.0

4.1

70

26.1

2.1

3.6

26.4

2.1

3.7

26.7

2.1

3.8

80

24.9

2.2

3.3

25.5

2.2

3.4

26.1

2.2

3.5

17

60

21.4

1.9

3.4

21.5

1.8

3.4

21.7

1.8

3.5

70

19.9

1.9

3.0

20.2

1.9

3.1

20.6

1.9

3.2

80

18.4

2.0

2.7

18.9

2.0

2.8

19.4

2.0

2.9

10

60

17.9

1.8

3.0

17.8

1.7

3.0

17.7

1.7

3.0

70

16.8

1.8

2.7

17.0

1.8

2.8

17.2

1.8

2.9

80

15.7

1.8

2.5

16.1

1.8

2.6

16.6

1.8

2.7

NOTE: ALL CAPACITIES ARE NET (KBTUH) WITH INDOOR FAN HEAT ALREADY DEDUCTED AT 1250 BTUH/1000 CFM.
**

For three-phase, decrease T.C. by 1.0 and S.C. by 0.7.

Air Handler

Coil

T.C.

S.C.

KW

MA12B

FC/MC35B

0.96

1.12

1.07

MA12B

FC/MC42B

0.96

1.12

1.07

MA14D

FC/MC48D

1.00

1.00

1.00

AHP36

0.93

1.12

1.07

F*FP040

0.95

1.12

1.07

F*FP042

0.95

1.12

1.07

MV16C*

FC/MC35C

0.89

1.09

0.97

MV16C*

FC/MC42C

0.89

1.09

0.97

MV16C*

FC/MC48C

0.98

0.94

0.92

MV20D*

FC/MC48D

0.98

0.94

0.92

AV36*

0.98

0.94

0.92

FC/MC/PC/UC42

0.96

1.12

1.07

HC42

0.99

1.00

0.99

HD36

1.00

1.00

1.00

Variable Speed
Furnace *

Coil

T.C.

S.C.

KW

(F,L)L8VB16

FC/MC/PC35B

0.92

1.10

0.97

FL9(C,V)B12

FC/MC/PC35B

0.92

1.08

0.96

(F,L)L8VC16

FC/MC/PC35C

0.92

1.10

0.97

(F,L)L8VC20

FC/MC/PC35C

0.92

1.08

0.96

FL9(C,V)C16

FC/MC/PC35C

0.93

1.13

1.02

FL9(C,V)C20

FC/MC/PC35C

0.93

1.10

0.97

(F,L)L8VB16

FC/MC/PC42B

0.92

1.10

0.97

FL9(C,V)B12

FC/MC/PC42B

0.92

1.08

0.96

(F,L)L8VC16

FC/MC/PC42C

0.92

1.10

0.97

(F,L)L8VC20

FC/MC/PC42C

0.92

1.08

0.96

FL9(C,V)C16

FC/MC/PC42C

0.93

1.13

1.02

FL9(C,V)C20

FC/MC/PC42C

0.93

1.10

0.97

(F,L)L8VC20

FC/MC/PC48C

0.98

0.95

0.93

FL9(C,V)C16

FC/MC/PC48C

0.98

0.96

0.94

FL9(C,V)C20

FC/MC/PC48C

0.98

0.95

0.93

FL9(C,V)D20

FC/MC/PC48D

0.98

0.95

0.93

(F,L)L8VC20

HC42

0.95

0.97

0.90

FL9(C,V)C16

HC42

0.96

0.97

0.90

FL9(C,V)C20

HC42

0.96

1.01

0.95

(F,L)L8VC20

HD36

0.96

0.95

0.90

FL9(C,V)C16

HD36

0.96

0.96

0.89

FL9(C,V)C20

HD36

0.96

0.96

0.89