HEATING PERFORMANCE DATA

CONDENSING UNIT MODEL NO

EABD-F048S, EABD-(T,W)048S**

EVAPORATOR COIL MODEL NO

FC/MC/PC/UC60

AIR TEMP.

ENTERING

OUTDOOR UNIT

AIR TEMP.

ENTERING

INDOOR COIL

ID CFM

1400

1600

1800

MBTUH

KW

C.O.P.

MBTUH

KW

C.O.P.

MBTUH

KW

C.O.P.

60

60

55.2

3.3

4.9

54.7

3.2

5.0

54.2

3.1

5.1

70

54.7

3.7

4.3

54.3

3.6

4.4

53.9

3.5

4.5

80

54.1

4.1

3.9

53.9

3.9

4.1

53.6

3.8

4.1

47

60

46.9

3.2

4.3

46.6

3.1

4.5

45.2

2.9

4.6

70

46.8

4.0

3.4

46.0

3.9

3.5

45.2

3.3

4.0

80

45.7

3.8

3.2

45.4

4.0

3.3

45.2

3.7

3.6

40

60

42.4

3.0

4.1

42.0

2.9

4.2

41.7

2.8

4.4

70

41.2

3.4

3.6

41.5

3.3

3.7

41.8

3.2

3.8

80

40.0

3.7

3.2

41.0

3.6

3.3

41.9

3.5

3.5

30

60

36.6

2.9

3.7

36.3

2.8

3.8

36.0

2.8

3.8

70

35.7

3.3

3.2

35.7

3.2

3.3

35.7

3.1

3.4

80

34.8

3.7

2.8

35.1

3.6

2.9

35.3

3.5

3.0

17

60

30.2

2.8

3.1

30.1

2.7

3.3

30.1

2.7

3.3

70

29.8

4.0

2.2

29.8

3.7

2.3

29.8

2.2

2.9

80

29.7

3.8

2.0

29.5

3.8

2.1

29.4

2.0

2.5

10

60

27.3

2.8

2.9

27.0

2.7

2.9

26.6

2.6

3.0

70

27.0

3.1

2.6

26.8

3.0

2.6

26.5

3.0

2.6

80

26.7

3.4

2.3

26.6

3.4

2.3

26.5

3.3

2.4

NOTE: ALL CAPACITIES ARE NET (KBTUH) WITH INDOOR FAN HEAT ALREADY DEDUCTED AT 1250 BTUH/1000 CFM.
**

For three-phase, decrease T.C. by 1.0 and S.C. by 0.7.

Air Handler

Coil

T.C.

S.C.

KW

MA16C

FC60C

1.00

1.00

1.00

MA20D

FC/MC60D

1.00

1.00

1.00

MA20D

MC61D

1.00

1.00

1.00

AHP/SHP48

1.00

1.02

1.02

AHP/SHP60

1.00

1.02

1.02

F*FV060*

0.99

0.97

0.96

MV20D*

FC/MC60D

0.99

0.98

0.97

MV20D*

MC61D

0.99

0.97

0.96

AV/SV48*

0.99

0.98

0.97

HC60

1.00

1.00

1.00

HD60

1.00

1.00

1.00

MC61

1.00

1.00

1.00

Variable Speed
Furnace *

Coil

T.C.

S.C.

KW

FL9(C,V)D20

FC/MC/PC60D

0.99

0.99

0.98

(F,L)L8VC16

FC/PC60C

0.99

1.00

0.99

(F,L)L8VC20

FC/PC60C

0.99

0.99

0.98

FL9(C,V)C16

FC/PC60C

0.98

1.00

0.98

FL9(C,V)C20

FC/PC60C

0.99

0.99

0.98

FL9(C,V)D20

HC60

0.99

0.99

0.98

(F,L)L8VC20

HD60

0.99

0.99

0.98

FL9(C,V)C20

HD60

0.99

0.99

0.98

FL9(C,V)D20

MC61D

0.99

0.98

0.97

Advertising