York E*BD-(T User Manual

Page 18

Advertising
background image

246819-BTG-H-0208

18

Unitary Products Group

Multipliers for determining the performance with other indoor sections.

NOTE: For dry bulb temperatures different than those listed (between 73-87 F), sensible capacity increases by 1060 BTUH per 1000 CFM per degree above the
listed temperature and decreases by 1060 BTUH per 1000 CFM per degree below the listed temperature.

COOLING PERFORMANCE DATA

OUTDOOR UNIT MODEL NO.

EABD-F018S

INDOOR COIL MODEL NO.

FC/MC/PC/UC18

CONDENSER

ENTERING AIR

TEMPERATURE

ID CFM

450

600

750

ID DB (°F)

80

80

75

80

80

80

80

75

80

80

80

80

75

80

80

ID WB (°F)

57

62

62

67

72

57

62

62

67

72

57

62

62

67

72

65

T.C.

16.8

19.2

19.5

21.9

24.5

19.0

20.7

20.8

23.1

25.8

21.2

22.3

22.1

24.3

27.1

S.C.

16.3

14.4

12.7

12.8

10.8

18.4

16.9

14.7

14.6

12.3

20.6

19.5

16.8

16.4

13.8

K.W.

1.1

1.1

1.1

1.1

1.1

1.1

1.1

1.1

1.1

1.1

1.1

1.1

1.1

1.1

1.1

75

T.C.

16.1

18.1

18.3

20.6

23.2

18.1

19.5

19.4

21.8

24.3

20.1

20.9

20.6

23.0

25.4

S.C.

15.6

13.9

12.1

12.3

10.3

17.6

16.3

14.1

14.0

11.7

19.5

18.8

16.0

15.8

13.0

K.W.

1.2

1.2

1.2

1.2

1.2

1.2

1.2

1.2

1.2

1.2

1.2

1.2

1.2

1.2

1.3

85

T.C.

15.4

17.1

17.0

19.2

21.8

17.2

18.3

18.1

20.4

22.7

19.0

19.6

19.2

21.6

23.6

S.C.

14.9

13.4

11.5

11.7

9.8

16.7

15.7

13.4

13.5

11.0

18.5

18.1

15.3

15.3

12.2

K.W.

1.2

1.3

1.3

1.3

1.3

1.3

1.3

1.3

1.3

1.3

1.3

1.3

1.3

1.3

1.4

95

T.C.

14.8

16.0

15.8

17.9

20.4

16.3

17.1

16.8

19.1

21.2

17.9

18.3

17.7

20.3

21.9

S.C.

14.2

12.9

10.9

11.1

9.3

15.8

15.1

12.7

12.9

10.4

17.5

17.4

14.6

14.7

11.4

K.W.

1.3

1.3

1.3

1.4

1.4

1.4

1.4

1.4

1.4

1.4

1.4

1.4

1.4

1.4

1.5

105

T.C.

14.0

14.9

14.7

16.8

19.1

15.4

16.0

15.6

17.8

19.7

16.9

17.0

16.5

18.7

20.4

S.C.

13.5

12.5

10.4

10.7

8.8

15.0

14.5

12.2

12.4

9.9

16.4

16.6

14.0

14.1

10.9

K.W.

1.4

1.4

1.4

1.5

1.5

1.5

1.5

1.5

1.5

1.5

1.5

1.5

1.5

1.5

1.6

115

T.C.

13.3

13.9

13.7

15.7

17.8

14.5

14.9

14.5

16.4

18.4

15.8

15.8

15.3

17.2

19.0

S.C.

12.8

12.0

9.9

10.2

8.3

14.1

13.9

11.7

11.8

9.4

15.4

15.8

13.4

13.4

10.5

K.W.

1.5

1.5

1.5

1.6

1.6

1.5

1.6

1.5

1.6

1.6

1.6

1.6

1.6

1.6

1.7

125

T.C.

12.5

12.9

12.7

14.6

16.5

13.7

13.7

13.4

15.1

17.0

14.8

14.5

14.1

15.7

17.5

S.C.

12.0

11.6

9.4

9.8

7.8

13.2

13.3

11.1

11.3

8.9

14.4

15.1

12.8

12.8

10.0

K.W.

1.6

1.6

1.6

1.7

1.7

1.6

1.6

1.6

1.7

1.7

1.7

1.7

1.7

1.7

1.8

NOTE: ALL CAPACITIES ARE NET (KBTUH) WITH INDOOR FAN HEAT ALREADY DEDUCTED AT 1250 BTUH/1000 CFM.

Air Handler

Coil

T.C.

S.C.

KW

MA08B

FC/MC18B

1.00

1.00

1.00

AHP18

1.00

0.92

1.00

F*FP024

1.00

0.92

1.00

MV12B

FC/MC18B

1.02

1.02

0.98

AV24

1.02

1.02

0.98

HC18

0.99

0.98

0.99

Variable Speed
Furnace

Coil

T.C.

S.C.

KW

(F,L)L8VA12

FC/MC/PC18A

1.02

1.01

0.97

FL9VA12

FC/MC/PC18A

1.02

1.01

0.97

FL9(C,V)B12

FC/MC/PC18B

1.03

1.02

0.98

(F,L)L8VA12

HC18

1.02

1.01

0.97

FL9VA12

HC18

1.02

1.01

0.97

Advertising
This manual is related to the following products: