Setting Up a Resilient

Link

You can set up resilient links on the Switch units within the stack using
the

define

command on the Resilience menu.

To set up a resilient link:

1 At the Top-level menu, enter:

feature resilience define

The following prompt is displayed:

Select unit for main link (1-4):

2 Enter the unit number for the main link that you wish to define.

The following prompt is displayed:

Select port for the main link (1,2,7):

3 Enter the port number for the main link that you wish to define.

The following prompt is displayed:

Select unit for standby link (1-4):

4 Enter the number of the unit for the standby link that you wish to define.

The following prompt is displayed:

Select port for the standby link (3,6):

5 Enter the number of the port for the standby link that you wish to define.

Displaying Resilient

Link Information

You can display detailed information for all resilient links set up within the
stack using the

detail

command on the Resilience menu.

To display resilient link information:

1 At the Top-level menu, enter:

feature resilience detail

2 The resilient link information is displayed as shown in the example below.

Index Main Link

State

Standby Link

State

Active Link Pair State

1

Unit 1 Port 1 Failed Unit 2 Port 1 Failed Standby

Operationa
l

2

Unit 1 Port 6 Failed Unit 2 Port 6 Active Standby

Operationa
l