The alarm events, The default alarm settings, The default alarm – 3Com 1100 User Manual

Page 208: Settings

Advertising
background image

208

C

HAPTER

10: RMON

sessions, the forwarding performance of the Switch is not affected but
you may experience slow response times from the web interface.

The Alarm Events

You can define up to 200 alarms for the Switch. The events that you can
define for each alarm are shown in Table 11.

The Default Alarm

Settings

A new or initialized Switch has two alarms defined for each port:

Broadcast bandwidth used

Percentage of errors over one minute

The default values and actions for each of these alarms are given in

Table 12

.

Table 11 Alarm Events

Event

Action

No action

Notify only

Send Trap.

Notify and filter port

Send Trap. Block broadcast and multicast
traffic on the port. Recovers with the unfilter
port
event.

Notify and disable port

Send Trap. Turn port off.

Notify and enable port

Send Trap. Turn port on.

Disable port

Turn port off.

Enable port

Turn port on.

Notify and switch resilient port

Send Trap. If port is the main port of a
resilient link pair then move to standby.

Notify and unfilter port

Send Trap. Stop blocking broadcast and
multicast traffic on the port.

Set Forwarding Mode to Store
and Forward

Set Forwarding Mode to
Fast Forward

System started

Software Upgrade report