!!!WARNIN

STAY AWAY FROM THE DOOR WHILE IT IS CLOSING - THE GA-

RAGE DOOR CAN CAUSE SEVERE INJURY!!!

When the timer finishes it’s count, the system will perform the door closing
procedure. When the door hits the obstruction, it should return to the open po-
sition. The Autocloser will attempt to close the door twice. When the Auto-
closer has finished its closing cycle, it will sense that the door has not closed
and transition to ‘malfunction disable’ mode. Note: the red disable LED will
begin to blink and the unit will beep once every 20 seconds. Press the disable
button to exit malfunction disable. The Autocloser will beep three times to
indicate that it is leaving the malfunction disable mode and returning to nor-
mal operational mode.

TIP: To minimize the time required to test, set the Autocloser delay time to
two minutes. (see Operation and Programming Item (4).)

E. Open the door. Simulate an obstruction in the doorway by placing a piece of

masking tape (non-clear) over one of the photo eye lenses.

!!!WARNING!!!

STAY AWAY FROM THE DOOR WHILE IT IS CLOSING - THE GA-

RAGE DOOR CAN CAUSE SEVERE INJURY!!!

When the timer finishes its count, the system will perform the door closing
procedure. The photo eye system should allow the door to move only slightly.
When the Autocloser has finished it’s closing cycle, it will sense that the door
has not closed and transition to malfunction disable mode. Note: the red dis-
able LED will begin to blink and the unit will beep once every 20 seconds.
Remove the tape from the photo eye. Press the disable button to exit malfunc-
tion disable mode. The Autocloser will beep three times to indicate that it is
leaving the malfunction disable mode and returning to normal operational
mode


F. Test for false reflections. Shut the garage door and switch the unit to ‘Set Up’

mode. Verify that the beeper does not make any noise. If the beeper is
sounding, make sure there is nothing in front of the Autocloser unit causing
false reflections.


G. Installation of your Autocloser unit is complete. If you purchased an optional

I-Opener, proceed to the I-Opener installation instructions. If you did not
purchase an I-Opener, proceed to the Operation and Programming instruc-
tions. If you did not purchase an I-Opener, one can be purchased and added
at any time by visiting our website: autocloser.com, or by calling 1-
877-SHUT DOOR (1-877-748-8366) or 972-690-5255.

!!!

!!!WARNING!!!

!!!