PROGRAM STEPS

MILLPWR

®

Operation Manual

Mirror

With “Mirror,” you can create a mirror image of an entire program or a section of a
program.

Note:

The steps being mirrored must precede the “Mirror” step.

To program a mirror:

•

From the PGM screen, press the

MORE STEPS

softkey.

•

Press the

MIRROR

softkey.

•

Enter the number of the first step and the last step
in the step range that you want to mirror.

•

Define the axis of reflection (a line that separates
the mirrored image from the original one).

For “1

ST

Axis Point,” enter the X- and Y-axes

coordinates for the axis of reflection.

For “2

ND

Axis Point,” enter the X- and Y-axes

coordinates for the axis of reflection.

•

Press the

USE

key.