PROGRAM STEPS

MILLPWR

®

Position/Drill

The position/drill function will move the table to the position
you want based upon your X- and Y-axes coordinates.

To program a position/drill step:

•

Press the

POS

key.

•

Enter the X- and Y-axes coordinates.

•

Enter a depth.

•

Press the

USE

key.

Note:

If the tool size and type listed in the "Tool" field
are incorrect, change the tool settings before run-
ning the program (refer to Programming a Tool
Step
).

Center Line

With the position/drill feature, you can also locate the midpoint of
two points or the center line of a circle.

To locate a center line:

•

Press the

CENTER LINE

softkey.

•

Locate the first edge and press the

ENTER

key.

•

Locate the second edge of your part and press the

ENTER

key.

•

If you are calculating the center of a circle, locate and enter a third point along
the diameter of the circle.

•

Press the

USE

key.