Set datum for the Z-axis:

•

Position the tool so that its tip touches the top surface
of the part.

•

Using the keypad, enter "0" into the "Z" field
(or press the Z = 0 softkey).

•

Press the

ENTER

key.

•

Press the

USE

key.

Datum has now been established for X, Y, and Z

It's a good idea to test the datum setting before programming. To confirm
that the new datum is correct:

•

Raise the tool and move the table until
both the X- and Y-axes displays read
"0.0000."

•

Lower the tool until it touches
the part.

•

Check the tool's position—the lower left
corner of the part should be directly
beneath the center point of your tool.

•

Now check the readout. If the Z-axis display says "0.0000," then the datum is
accurate. If a value other than 0.0000 appears in the Z-axis display, repeat the
procedure for establishing datum.