G1000 system message advisories, Appendix a, Mfd & pfd message advisories – Garmin G1000 Mooney M20TN User Manual

Page 452

Advertising
background image

190-00647-01 Rev. B

Garmin G1000 Pilot’s Guide for the Mooney M20M/M20R/M20TN

SY

STEM

O

VER
VIEW

FLIGHT

INSTRUMENTS

EIS

AUDIO P

ANEL

& CNS

FLIGHT

MANA

GEMENT

HAZARD

AV

OID
ANCE

AFCS

ADDITIONAL

FEA
TURES

APPENDICES

INDEX

441

APPENDIX A

G1000 SYSTEM MESSAGE ADVISORIES

This section describes various G1000 system message advisories. Certain messages are issued due to an LRU

or an LRU function failure. Such messages are normally accompanied by a corresponding red ‘X’ annunciation
as shown previously in the G1000 System Annunciation section.

NOTE:

This Section provides information regarding G1000 message advisories that may be displayed by

the system. Knowledge of the aircraft, systems, flight conditions, and other existing operational priorities
must be considered when responding to a message. Always use sound pilot judgment. The POH takes
precedence over any conflicting guidance found in this section.

MFD & PFD MESSAGE ADVISORIES

Message

Comments

DATA LOST – Pilot stored data was
lost. Recheck settings.

The pilot profile data was lost. System reverts to default pilot profile and settings. The
pilot may reconfigure the MFD & PFDs with preferred settings, if desired.

XTALK ERROR – A flight display
crosstalk error has occurred.

The MFD and PFDs are not communicating with each other. The G1000 system should
be serviced.

PFD1 SERVICE – PFD1 needs service.
Return unit for repair.

The PFD and/or MFD self-test has detected a problem. The G1000 system should be
serviced.

MFD1 SERVICE – MFD1 needs
service. Return unit for repair.
MANIFEST – PFD1 software
mismatch, communication halted.

The PFD and/or MFD has incorrect software installed. The G1000 system should be
serviced.

MANIFEST – MFD1 software
mismatch, communication halted.
PFD1 CONFIG – PFD1 config error.
Config service req’d.

The PFD and/or MFD configuration settings do not match backup configuration
memory. The G1000 system should be serviced.

MFD1 CONFIG – MFD1 config error.
Config service req’d.
SW MISMATCH – GDU software
version mismatch. Xtalk is off.

The MFD and PFDs have different software versions installed. The G1000 system
should be serviced.

PFD1 COOLING – PFD1 has poor
cooling. Reducing power usage.

The PFD and/or MFD is overheating and is reducing power consumption by dimming
the display. If problem persists, the G1000 system should be serviced.

MFD1 COOLING – MFD1 has poor
cooling. Reducing power usage.
PFD1 KEYSTK – PFD1 [key name] Key
is stuck.

A key is stuck on the PFD and/or MFD bezel. Attempt to free the stuck key by pressing
it several times. The G1000 system should be serviced if the problem persists.

MFD1 KEYSTK – MFD [key name] Key
is stuck.
CNFG MODULE – PFD1 configuration
module is inoperative.

The PFD1 configuration module backup memory has failed. The G1000 system should
be serviced.

PFD1 VOLTAGE – PFD1 has low
voltage. Reducing power usage

The PFD1 voltage is low. The G1000 system should be serviced.

MFD1 VOLTAGE – MFD1 has low
voltage. Reducing power usage

The MFD voltage is low. The G1000 system should be serviced.

Advertising
This manual is related to the following products: