Defining zones – Velleman VMB1TC User Manual

Page 49

Advertising
background image

VMB1TC Temperature controller manual – rev 5.0

49

Defining zones


It could be interesting to group different sensors in a zone. When that zone is selected, all operations on the controller will
be applicable for all sensors that belong to that zone. This way operating the system can be greatly facilitated.
It is possible to define up to 7 zones e.g. ground floor, second floor, bedrooms …
Default temperature sensors are not assigned to a zone. To assign them to a zone the procedure below should be
followed.


1. Press the ‘Location’ button repeatedly until the

sensor that will to be added to a zone is displayed.

2. Press and hold the ‘Menu’ button for ±4 seconds to

open the extended menu.

3. Scroll through the extended menu using the ↑ or ↓

button until the ‘Sensor settings’ item appears.

4. Select the sensor settings menu with the → button.


5. Scroll through the sensor settings menu using the ↑

or ↓ button until the ‘Zone number’ item appears

6. Select the zone number menu with the → button.

7. Change the zone with the ↑ or ↓ button.

Option ‘---‘ indicates that the sensor does not belong
to a zone.


8. Confirm with the → button.

Location

5

Menu

Mode

Bedroom
Zone 1

Location

5

Menu

Mode

Bedroom 1

Mo 14:32 16

Location

5

Menu

Mode

Bedroom 1
Program

Location

5

Menu

Mode

Bedroom 1
Sensor settings

Location

5

Menu

Mode

Bedroom 1
Operating mode

Location

5

Menu

Mode

Bedroom 1
Zone number

Location

5

Menu

Mode

Bedroom 1
________

Location

5

Menu

Mode

Bedroom 1
Zone number

Advertising