Velleman VMB1TC User Manual

Page 5

Advertising
background image

VMB1TC Temperature controller manual – rev 5.0

5

Programming

A program instruction can switch a sensor between comfort, day, night or anti-freeze mode at a certain time.

Possibility to enter program instructions that are applicable for all zones or for all sensors in a defined zone.

Up to 31 program instructions can be saved per sensor or zone.

Program types:

• day programs: every Monday, Tuesday, Wednesday, Thursday, Friday, Saturday or Sunday

• working day programs: from Monday up to and including Friday or Saturday

• weekend programs: every Saturday and Sunday

• week programs: every day

Wake-up time and sleep time can be used inside program instructions.


Power supply

Required power supply: 12 to 18VDC

Consumption backlight off: 25mA

Maximum consumption (LEDs activated, backlight max.): 50mA

Battery emergency power supply: 3V Lithium battery (CR2032 included)

Consumption emergency power supply not active: 0.5µA

Consumption emergency power supply activated: 200µA

Display warning when battery needs replacement


Dimensions

Module (L x B x H): 66 x 44 x 40mm

Dimensions including cover plate (L x B x H): 118 x 80 x 40mm

Cover plate not included

Advertising