Banks Power Universal Car & Truck: (Gas or Diesel ’50 - 14 Universal) Water-Methanol: Straight-Shot and Double Shot, Universal applications User Manual
Page 11
97650 v.1.0
11
injection nozzle(s) will spray perpendicular
to intake airflow direction. Deburr sharp
edges. See Figure 23
4.
Use 1/8”-27 NPT tap to thread air
intake duct. Ensure tap is perpendicular
to air intake duct surface to avoid leaks.
Check the thread depth as you tap by
periodically removing the tap and screw-
ing the injection nozzle into the tapped
hole. The injection nozzle should thread
in 3 to 3
1
⁄
2
turns hand tight. Do not install
the injection nozzle in place at this time.
See Figure 24
: Running the tap
too deeply can prevent injection
nozzle(s) from properly sealing.
5.
Apply provided sealant tape (P/N
91099) to threads of injection nozzle(s) to
be used and thread each injection nozzle
into a 90-degree female Push-Lock fitting
(P/N 45122). Tighten 2-3 turns past hand-
tight. See Figure 25
: Sealant tape must
be applied properly to avoid leaks.
Clean threads with rag. Start at second
thread in from end. Wrap tightly follow-
ing direction of threads to avoid tape
pealing away from Injection Nozzle when
threaded into fitting. Overlap tape, moving
towards base of threads creating two lay-
ers of sealant tape. See Figure 26
Figure 26
Figure 25
Figure 24
Figure 23
Drill and tap holes
perpendicular to air
intake duct surface