Plumbing (double-shot), Egt thermocouple – Banks Power Universal Car & Truck: (Gas or Diesel ’50 - 14 Universal) Water-Methanol: Straight-Shot and Double Shot, Universal applications User Manual
Page 14
14
97650 v.1.0
Plumbing (Double-Shot)
: Route and secure tub-
ing where it will not interfere with
moving or hot engine components.
Avoid sharp turns that may kink
tubing and sharp edges that may
damage tubing.
: Cut tubing using
a Pocket or X-Acto knife to avoid
pinching the tubing. Pinching the
tubing will cause it to not seat
properly.
1.
Secure one end of 1/4” Nylon tubing
(P/N 45140) into Push-Lock fitting on high
capacity tank by firmly pushing tubing into
Push-Lock fitting. Carefully pull on tubing
to ensure tubing is secured properly.
2.
Route tubing to injection pump
inlet. Cut tubing, allowing approximately
1/2” for securing into injection pump.
Properly secure tubing into injection pump
inlet.
: Make all cuts as
square as possible to avoid leaks.
3.
Route tubing from injection pump out-
let to port #1 of “Y” fitting (P/N 45123).
Properly cut tubing and secure into “Y”
fitting. See Figure 30
4.
Secure tubing in port #2 of “Y” fitting
and route tubing to inlet of check valve.
Properly cut and secure tubing in Push-
Lock check valve.
5.
Secure tubing in port #3 of “Y” fitting
and route tubing to “IN” port of solenoid.
Properly cut and secure tubing in Push-
Lock on solenoid. See Figure 31
6.
Secure tubing in outlet of check valve
and route to the first injection nozzle
assembly. Properly cut tubing and secure
into injection nozzle assembly.
7.
For two injection nozzles, secure tub-
ing in Push-Lock fitting of solenoid labeled
“OUT” and route to the second injection
nozzle assembly. Properly cut tubing and
secure into injection nozzle assembly.
8.
For three injection nozzles, secure
tubing in Push-Lock fitting of solenoid
labeled “OUT” and route to port #1 of “Y”
fitting (P/N 45123). Properly cut tubing
and secure in “Y” fitting. Secure tubing
in port #2 of “Y” fitting and route tubing
to the second injection nozzle assembly.
Properly cut tubing and secure into injec-
tion nozzle assembly. Repeat for the third
injection nozzle assembly using the #3
port of the “Y” fitting.
EGT Thermocouple
: An EGT thermocouple (P/N
63042) is only provided in the Double-Shot
system. If you purchased the Straight-
Shot system, proceed to the Wiring
and Controller section. See Figure 32
1.
The thermocouple monitors the tem-
perature of the exhaust gases entering
the turbocharger at the turbine housing.
Figure 32
Figure 31
Outlet
Inlet