Page 8
8
96511 v.7.0
2.
Locate the Factory Powertrain
control Module (PcM) on the
passenger side firewall in the engine
compartment. See Figure 2.
3.
Disconnect the left connector from
the PcM by opening the locking tab as
shown in Figure 3.
4.
Insert the male connector on the
Six Gun Tuner PCM harness into the
female connector on the factory
harness. Insert the female connector
on the Six Gun Tuner PCM harness
onto the male connector on the
factory PcM. Lock the connection by
closing the locking tabs. Secure the
connectors behind the oil reservoir
and away from any heat source.
5.
Secure the Six-Gun Tuner PCM
harness along the rail on the firewall
with the supplied cable ties.
Note: Do not connect the Six-Gun
PCM harness to the tuner. It will be
connected in step 17.
6.
Locate the Six-Gun Turbo/In-cab
harness. Place the harness over the
driver side fuse box. Route the turbo
actuator connector on the Turbo/
in-cab harness along the rail on the
rear of the engine compartment to the
turbo.
7.
Unplug the turbo actuator
connector shown in Figure 4. The
turbo actuator cable connector can
be unplugged by sliding the red safety
slide down, pressing the locking
button, and then pulling on the
connector.
8.
Plug the female Six-Gun turbo
actuator connector into the male
factory turbo actuator connector.
Plug the female factory turbo actuator
connector into the male Six-Gun turbo
actuator connector.
9.
Secure the Six-Gun turbo actuator
connector wires to the firewall rail
using the supplied zip ties. Secure the
wires away from any heat source.
Figure 2: Six-Gun Harness routing