Grain Systems Bucket Elevtors, Conveyors, Series II Sweeps PNEG-970 User Manual

Page 19

Advertising
background image

PNEG-970 S2 Hopper w/ Collector Ring

19

Assembly

2. WIRE THE COLLECTOR RING

A. Attach the 1" liquid-tight flex conduit coupling to one end of the 1" x 16" liquid-tight flex

conduit.

B. Attach the 1" x 45 degree liquid-tight flex conduit coupling to the other end of the 1" x 16"

liquid tight flex conduit.

C. Remove the protective housing from the collector ring.

D. Feed the multi-conductor cord through the conduit assembly and the 1" conduit hub on the

collector ring.

E. Attach the 1" x 45 degree liquid-tight flex conduit coupling to the 1" conduit hub on the

collector ring. Be sure to turn the conduit assembly down .

Electrical controls and wiring should be installed by a qualified electrician.
The motor disconnect switches and conductor cables should comply with
the National Electrical code and any local codes which apply. Reset and
motor starting stations should be located so that the operator can see that
all personnel are clear of the equipment.

collector ring hub

multi-conductor cord

1" x 45 degree flex
conduit coupling

1" x 16" flex conduit

1" flex conduit
coupling

Note:The liquid-tight flex conduit may need to be trimmed to length.

Advertising