Anchor bolt placement, Foundations – Grain Systems Tanks PNEG-1095 User Manual

Page 21

Advertising
background image

5. Foundations

PNEG-1095 FCDL 4.00" Corrugation Externally Stiffened Grain Bin

21

Anchor Bolt Placement

1. Having poured and leveled the concrete, use the center stake and straight 2 x 4 again to find the bolt

circle radius for the outside hold down brackets.

2. Select a starting point and stretch a pre-measured chord (“E” chord distance in

Figure 5G

) along the

imaginary circle formed by the bolt circle radius. This will give you the bolt locations on the bolt
circle radius.

3. Take into consideration the placement of these bolts so as not to interfere with the positions of bin

doors and transitions. (Refer to the following anchor bolt chart on

Page 22

for necessary radius and

chord lengths.) Take the time and work carefully since accuracy is important.

NOTE: The top edge of slab where the bin wall sets must be held to within 1/8" of level.

NOTE: The above anchor bolt radii and dimensions are for the FCDL series only. For NC commercial

tanks, refer to the NC commercial section of the foundation recommendations in PNEG-318.

Figure 5F Anchor Bolt Detail (Typical)

Figure 5G

Anchor Bolt Chart for FCDL Tank

Bin Diameter

“B” Bolt Circle

Radius

# of Anchors

“E” Chord Distance

12'

6' - 3-1/4''

8

4' - 9-5/8''

15'

7' - 9-1/8''

10

4' - 9-9/16''

18'

9' - 3-1/16''

12

4' - 9-1/2''

21'

10' - 8-15/16''

14

4' - 9-3/8''

24'

12' - 2-7/8''

16

4' - 9-5/16''

27'

13' - 8-3/4''

18

4' - 9-3/16''

30'

15' - 2-11/16''

20

4' - 9-3/16''

33'

16' - 8-9/16''

22

4' - 9-1/16''

36'

18' - 2-1/2''

24

4' - 9-1/16''

42'

21' - 2-5/16''

28

4' - 8-15/16''

48'

24' - 2-1/8''

32

4' - 8-7/8''

54'

27' - 1-15/16''

36

4' - 8-13/16''

60'

30' - 1-3/4''

40

4' - 8-3/4''

Advertising