Sidedraw installation, Installation – Grain Systems Tanks PNEG-1095 User Manual

Page 65

Advertising
background image

6. Installation

PNEG-1095 FCDL 4.00" Corrugation Externally Stiffened Grain Bin

65

Sidedraw Installation

Figure 6V Sidedraw Installation

Sidedraw Chute Installation

Number of Rings

Starting Dimension

Number of Chutes

Horizontal Location for First Chute

14

34"

12

Center between Stiffeners

13

54"

10

Middle of Sheet

12

42"

9

Middle of Sheet

11

62"

7

Middle of Sheet

10

50"

6

Middle of Sheet

9

38"

5

Middle of Sheet

8

58"

4

Middle of Sheet

7

48"

3

Middle of Sheet

(See Figure 6Z on
Page 67.)