6. Installation
PNEG-1095 FCDL 4.00" Corrugation Externally Stiffened Grain Bin
65
Sidedraw Installation
Figure 6V Sidedraw Installation
Sidedraw Chute Installation
Number of Rings
Starting Dimension
Number of Chutes
Horizontal Location for First Chute
14
34"
12
Center between Stiffeners
13
54"
10
Middle of Sheet
12
42"
9
Middle of Sheet
11
62"
7
Middle of Sheet
10
50"
6
Middle of Sheet
9
38"
5
Middle of Sheet
8
58"
4
Middle of Sheet
7
48"
3
Middle of Sheet
Advertising