6. Installation

54

PNEG-1095 FCDL 4.00" Corrugation Externally Stiffened Grain Bin

Door Placement

Unloading from Bin Door

1. Unloading from the door opening should be done only with the use of an auger hood and having the

auger inserted through the opening all the way to the center of the grain bin.

2. Unloading directly from the door opening should be limited to grain bins no larger than 24' in diameter

and grain depths no greater than 18' total.

3.

See Figure 6L

for door placement. Refer the 2 ring door instruction on

Page 55

and round access

door installation instruction on

Page 63

for details on installing these doors.

NOTE: These pages show the standard door usage and placement.

NOTE: Special bins/silos are sometimes purchased that utilize a special 2 ring door or an alternate.

See special instructions that may be included with these bins/silos.

Figure 6L

CAUTION

Improperly unloading grain through door opening may cause grain bin failure.
Unloading directly through the door opening should be limited to grain bins no
larger than 24' (7.32 m) diameter and grain depths no greater than 18' (5.49 m).
Unloading from the door opening should be done only with use of an auger hood

with the auger inserted through the opening all the way to the center of the bin.