Options for 2 ring door, Inner door auger hood – Grain Systems Tanks PNEG-1095 User Manual

Page 60

Advertising
background image

6. Installation

60

PNEG-1095 FCDL 4.00" Corrugation Externally Stiffened Grain Bin

Options for 2 Ring Door

Inner Door Auger Hood

12' (3.66 m) - 24' (7.32 m) Diameters Only

1. Remove bolts, lock washers and nuts along each side of large square opening on the inner

door panel.

2. Position auger shield as shown in

Figure 6P

and bolt to underside of top angle with bolt heads under

shield. Replace bolts, lock washers and nuts through inner door panel and auger shield.

(See Figure 6P.)

3. Attach inner door panel to inner bin door and outer door panel to the outer bin door.

Figure 6P

CAUTION

Improperly unloading grain through door opening may cause grain bin failure.
Unloading directly through the door opening should be limited to grain bins no
larger than 24' (7.32 m) diameter and grain depths no greater than 18' (5.49 m).
Unloading from the door opening should be done only with use of an auger
hood with the auger inserted through the opening all the way to the center
of the bin.