Examples – Grain Systems PNEG-501 User Manual

Page 10

Advertising
background image

10

Fan/Heater Application

EXAMPLES

SITUATION:

On farm aeration of dry soybeans. 42" diameter, 9 rings, NSL series farm bin
with 24" eave height. A flush floor aeration system with one fan will be used.

1.

AVE GRAIN DEPTH, peaked = 24' + (42' /12) = 27.5'

2.

Select 1/10 CFM/BU aeration rate for beans

3.

From the STATIC PRESSURE TABLE for BEANS at 28' (use the next
higher value or approximate) and 1/10 cfm/bu the static pressure is .91" of
water.
.91" water column

4.

Bin capacity, BUSHELS
27.5' x 0.6594 x 42' x 42' = 31988 BUSHELS

5.

Required TOTAL AIRFLOW, CFM
0.1 cfm/bu x 31988 bu = 3199 CFM

6.

From the FAN PERFORMANCE TABLE for vane axial fans, at 1" (0.91")
static pressure and 3500 cfm (closest to 3199 cfm), the appropriate fan would
be a 1.5hp-18"

7.

Number of ROOF VENTS
3500 CFM ÷ 1800 cfm/vent = 1.94, therefore 2 vents

8.

PERFORATED AREA of floor, sq ft
3199 cfm ÷ 30 cfm/sq ft = 106.6 sq ft, minimum

9.

SUPPLY DUCT AREA, sq ft
3199 cfm ÷ 2000 cfm/sq ft =1.60 sq ft, minimum
ID of supply duct for 12" deep tunnel = 1.6 sq ft ÷ 1.0 ft = 1.6 ft or 1.8"

10.

Maximum distance between ducts and binwall = 27.5' ч 4 = 6.9'