7

Fan/Heater Application

FAN APPLICATION GUIDE

NO

YES

MAYBE

YES

NO

MAYBE

1750RPM Centrifugal Fans

1750RPM Centrifugal fans are normally high performance, medium static pressure

fans. They are normally used for aeration or drying on shorter tanks or when low

resistance grains (corn, soybeans) are processed. These fans may be used with gas

heaters, either mounted on the inlet side of the fan or downwind on the outlet side.

Greater airflow is attained when the heaters are mounted downwind. Fans larger

than 30HP require a 17" tall plenum (floor) so the transition will clear. The

application should be looked at very closely when aerating unusually tall tanks or

high resistance grains (wheat, milo).

3500RPM Centrifugal Fans

3500RPM Centrifugal fans are normally medium preformance high static pressure

fans. They are normally used for aeration on taller tanks or when high resistance

grains (wheat, milo) are processed. These fans are not normally used with heaters.

Although these fans are less expensive than 1750RPM fans they are not normally

used on shallower grain depths because 1750RPM fans give much greater perfor-

mance for the horsepower at shallow depths thus less horsepower is required.