Pressure chart, Static pressure chart for wheat – Grain Systems PNEG-501 User Manual

Page 30

Advertising
background image

30

Fan/Heater Application

PRESSURE CHART

STATIC PRESSURE CHART FOR WHEAT

3

2

1

3/4

1/2

1/3

1/4

1/5

1/7

1/10

1/15

1/20

2

0.80

0.69

0.59

0.57

0.55

0.53

0.52

0.52

0.51

0.51

0.51

4

1.80

1.32

0.88

0.78

0.68

0.62

0.59

0.57

0.55

0.54

0.52

0.52

6

3.68

2.46

1.39

1.15

0.92

0.78

0.71

0.66

0.62

0.58

0.55

0.54

8

6.58

4.18

2.14

1.69

1.27

1.00

0.87

0.79

0.71

0.64

0.60

0.57

10

10.64

6.54

3.14

2.40

1.72

1.29

1.08

0.96

0.83

0.73

0.65

0.61

12

15.99

9.62

4.41

3.31

2.28

1.65

1.35

1.17

0.97

0.83

0.72

0.66

14

13.47

5.98

4.41

2.97

2.08

1.66

1.42

1.15

0.95

0.80

0.72

16

18.16

7.85

5.72

3.77

2.59

2.03

1.71

1.35

1.09

0.89

0.79

18

10.05

7.24

4.71

3.17

2.45

2.04

1.58

1.24

0.99

0.87

20

12.59

9.00

5.78

3.83

2.93

2.41

1.84

1.42

1.11

0.95

22

15.48

10.99

6.98

4.58

3.47

2.83

2.13

1.62

1.24

1.05

24

18.74

13.23

8.33

5.41

4.06

3.29

2.45

1.84

1.38

1.15

26

15.72

9.82

6.32

4.72

3.80

2.80

2.08

1.53

1.27

28

18.48

11.46

7.32

5.43

4.36

3.18

2.34

1.70

1.39

30

13.25

8.41

6.21

4.96

3.59

2.62

1.88

1.53

32

15.21

9.59

7.05

5.60

4.04

2.92

2.08

1.67

34

17.32

10.86

7.95

6.30

4.51

3.24

2.29

1.83

36

19.60

12.23

8.92

7.04

5.02

3.58

2.51

1.99

38

13.69

9.95

7.84

5.56

3.94

2.74

2.16

40

15.25

11.05

8.68

6.14

4.33

2.99

2.35

42

16.92

12.22

9.58

6.74

4.74

3.25

2.54

44

18.68

13.46

10.53

7.39

5.17

3.53

2.74

46

14.77

11.53

8.06

5.62

3.82

2.95

48

16.15

12.58

8.77

6.09

4.12

3.18

50

17.61

13.69

9.52

6.59

4.44

3.41

52

19.14

14.85

10.30

7.11

4.77

3.65

54

16.07

11.12

7.65

5.12

3.91

56

17.35

11.97

8.22

5.48

4.17

58

18.68

12.86

8.80

5.85

4.45

60

20.06

13.79

9.42

6.24

4.73

62

14.75

10.05

6.65

5.03

64

15.75

10.71

7.07

5.33

66

16.79

11.40

7.50

5.65

68

17.87

12.11

7.95

5.97

70

18.99

12.84

8.41

6.31

72

20.14

13.60

8.89

6.66

74

14.38

9.38

7.02

76

15.19

9.89

7.39

78

16.02

10.41

7.77

80

16.88

10.95

8.16

82

17.76

11.50

8.56

84

18.67

12.07

8.97

86

19.61

12.66

9.40

88

13.26

9.83

90

13.88

10.28

92

14.51

10.73

94

15.16

11.20

96

15.82

11.68

98

16.50

12.17

100

17.20

12.68

.50" Water Column have been Added To Static Pressure to Account for System Loss

Static Pressures are Calculated Using a 1.5 Factor Applied to Shedd's Data

GRAIN

DEPTH

FEET

Static Pressure (inches of water column)

Airflow Rate (cfm per bushel)