Pressure chart, Static pressure chart for wheat (w/ stirring) – Grain Systems PNEG-501 User Manual

Page 17

Advertising
background image

17

Fan/Heater Application

PRESSURE CHART

STATIC PRESSURE CHART FOR WHEAT (W/ STIRRING)

3

2

1

3/4

1/2

1/3

1/4

1/5

1/7

1/10

1/15

1/20

2

0.73

0.65

0.57

0.55

0.53

0.52

0.52

0.51

0.51

0.51

4

1.50

1.13

0.79

0.72

0.64

0.59

0.57

0.56

0.54

0.53

0.52

0.51

6

2.94

2.00

1.18

1.00

0.82

0.71

0.66

0.63

0.59

0.56

0.54

0.53

8

5.16

3.32

1.75

1.41

1.09

0.88

0.78

0.72

0.66

0.61

0.57

0.55

10

8.27

5.13

2.52

1.96

1.43

1.10

0.95

0.85

0.75

0.67

0.61

0.59

12

12.37

7.49

3.50

2.65

1.87

1.38

1.15

1.01

0.86

0.75

0.67

0.62

14

17.56

10.45

4.70

3.50

2.39

1.71

1.39

1.20

1.00

0.84

0.73

0.67

16

14.04

6.14

4.50

3.01

2.10

1.67

1.43

1.15

0.95

0.80

0.72

18

18.31

7.82

5.67

3.73

2.55

2.00

1.68

1.33

1.07

0.88

0.78

20

9.77

7.02

4.55

3.06

2.37

1.97

1.53

1.21

0.97

0.85

22

11.98

8.54

5.47

3.63

2.78

2.29

1.75

1.36

1.06

0.92

24

14.49

10.26

6.50

4.26

3.23

2.64

1.99

1.53

1.17

1.00

26

17.29

12.17

7.64

4.96

3.73

3.03

2.26

1.71

1.29

1.09

28

20.39

14.29

8.90

5.73

4.28

3.46

2.56

1.91

1.42

1.19

30

16.61

10.28

6.56

4.88

3.92

2.87

2.12

1.56

1.29

32

19.15

11.77

7.47

5.52

4.41

3.21

2.35

1.71

1.40

34

13.40

8.44

6.21

4.95

3.58

2.60

1.87

1.52

36

15.14

9.49

6.95

5.52

3.97

2.86

2.04

1.64

38

17.02

10.61

7.75

6.13

4.38

3.14

2.22

1.77

40

19.03

11.81

8.59

6.77

4.82

3.44

2.41

1.92

42

13.09

9.49

7.46

5.29

3.75

2.61

2.06

44

14.44

10.44

8.19

5.78

4.08

2.82

2.22

46

15.88

11.44

8.96

6.30

4.42

3.04

2.38

48

17.39

12.50

9.76

6.84

4.79

3.28

2.55

50

18.99

13.62

10.61

7.41

5.17

3.52

2.73

52

14.79

11.50

8.01

5.57

3.78

2.92

54

16.02

12.44

8.64

5.98

4.04

3.11

56

17.30

13.41

9.29

6.42

4.32

3.32

58

18.65

14.43

9.98

6.87

4.60

3.53

60

20.05

15.50

10.69

7.34

4.90

3.74

62

16.61

11.43

7.82

5.21

3.97

64

17.76

12.19

8.33

5.53

4.20

66

18.96

12.99

8.86

5.87

4.45

68

20.21

13.82

9.40

6.21

4.70

70

14.67

9.96

6.56

4.95

72

15.56

10.54

6.93

5.22

74

16.48

11.14

7.31

5.50

76

17.42

11.76

7.70

5.78

78

18.40

12.40

8.10

6.07

80

19.41

13.06

8.51

6.37

82

20.45

13.74

8.94

6.68

84

14.43

9.37

7.00

86

15.15

9.82

7.32

88

15.89

10.28

7.65

90

16.64

10.75

8.00

92

17.42

11.24

8.35

94

18.22

11.74

8.71

96

19.04

12.25

9.07

98

19.88

12.77

9.45

100

13.30

9.84

.50" Water Column have been Added To Static Pressure to Account for System Loss

Static Pressures are Calculated Using a 1.15 Factor Applied to Shedd's Data

GRAIN

DEPTH

FEET

Static Pressure (inches of water column)

Airflow Rate (cfm per bushel)

Advertising