Fan/Heater Application

PRESSURE CHART

STATIC PRESSURE CHART FOR RAPE

3

2

1

3/4

1/2

1/3

1/4

1/5

1/7

1/10

1/15

1/20

2

1.09

0.89

0.69

0.64

0.59

0.56

0.55

0.54

0.53

0.52

0.51

0.51

4

3.03

2.12

1.27

1.07

0.88

0.75

0.69

0.65

0.61

0.57

0.55

0.54

6

6.53

4.30

2.28

1.81

1.36

1.07

0.92

0.84

0.74

0.67

0.61

0.58

8

11.81

7.52

3.74

2.87

2.05

1.51

1.26

1.10

0.93

0.80

0.70

0.65

10

19.06

11.88

5.67

4.27

2.95

2.10

1.69

1.44

1.17

0.97

0.81

0.73

12

17.47

8.09

6.02

4.06

2.82

2.22

1.87

1.47

1.17

0.95

0.83

14

11.04

8.13

5.40

3.68

2.86

2.37

1.82

1.42

1.11

0.96

16

14.54

10.62

6.97

4.69

3.59

2.95

2.23

1.70

1.30

1.10

18

18.60

13.51

8.78

5.84

4.44

3.62

2.70

2.03

1.51

1.26

20

16.79

10.83

7.14

5.39

4.37

3.23

2.39

1.75

1.43

22

20.50

13.13

8.59

6.45

5.20

3.81

2.79

2.01

1.63

24

15.69

10.20

7.62

6.12

4.46

3.23

2.31

1.85

26

18.50

11.97

8.91

7.13

5.16

3.72

2.62

2.08

28

13.89

10.30

8.22

5.92

4.24

2.97

2.34

30

15.98

11.82

9.40

6.74

4.80

3.33

2.61

32

18.24

13.45

10.68

7.63

5.41

3.73

2.91

34

15.19

12.04

8.57

6.05

4.15

3.22

36

17.06

13.49

9.58

6.74

4.60

3.55

38

19.05

15.04

10.65

7.47

5.08

3.91

40

16.68

11.78

8.24

5.58

4.28

42

18.42

12.98

9.05

6.11

4.67

44

20.25

14.24

9.91

6.67

5.08

46

15.56

10.81

7.25

5.52

48

16.95

11.75

7.86

5.97

50

18.41

12.74

8.50

6.44

52

19.93

13.76

9.17

6.93

54

14.84

9.86

7.45

56

15.95

10.58

7.98

58

17.11

11.33

8.53

60

18.32

12.11

9.11

62

19.57

12.92

9.70

64

13.75

10.32

66

14.61

10.95

68

15.51

11.61

70

16.43

12.28

72

17.38

12.98

74

18.35

13.70

76

19.36

14.44

78

20.40

15.20

80

15.98

82

16.78

84

17.61

86

18.45

88

19.32

90

20.21

92
94
96
98

100

.50" Water Column have been Added To Static Pressure to Account for System Loss

Static Pressures are Calculated Using a 1.5 Factor Applied to Shedd's Data

GRAIN

DEPTH

FEET

Static Pressure (inches of water column)

Airflow Rate (cfm per bushel)