22

Fan/Heater Application

PRESSURE CHART

STATIC PRESSURE CHART FOR EARCORN

3

2

1

3/4

1/2

1/3

1/4

1/5

1/7

1/10

1/15

1/20

2

0.51

0.51

4

0.57

0.53

0.51

0.51

6

0.69

0.60

0.53

0.52

0.51

0.51

8

0.92

0.71

0.57

0.54

0.52

0.51

0.51

0.51

10

1.28

0.89

0.62

0.58

0.54

0.52

0.51

0.51

0.51

12

1.78

1.13

0.70

0.62

0.56

0.53

0.52

0.52

0.51

0.51

14

2.45

1.46

0.79

0.68

0.59

0.55

0.53

0.52

0.51

0.51

16

3.33

1.89

0.92

0.76

0.63

0.57

0.54

0.53

0.52

0.51

0.51

18

4.41

2.42

1.08

0.86

0.68

0.59

0.56

0.54

0.53

0.52

0.51

0.51

20

5.74

3.06

1.27

0.97

0.74

0.62

0.58

0.56

0.53

0.52

0.51

0.51

22

7.33

3.83

1.50

1.11

0.81

0.66

0.60

0.57

0.54

0.52

0.51

0.51

24

9.20

4.74

1.77

1.27

0.89

0.70

0.63

0.59

0.55

0.53

0.52

0.51

26

11.37

5.79

2.07

1.46

0.98

0.75

0.66

0.61

0.56

0.54

0.52

0.51

28

13.87

6.99

2.43

1.67

1.09

0.80

0.69

0.63

0.58

0.55

0.53

0.52

30

16.71

8.36

2.83

1.92

1.21

0.86

0.73

0.66

0.59

0.55

0.53

0.52

32

19.91

9.91

3.28

2.19

1.34

0.93

0.77

0.69

0.61

0.56

0.53

0.52

34

11.63

3.78

2.49

1.49

1.00

0.81

0.72

0.63

0.57

0.54

0.53

36

13.55

4.34

2.83

1.66

1.08

0.86

0.75

0.65

0.59

0.55

0.53

38

15.67

4.95

3.20

1.84

1.18

0.92

0.79

0.67

0.60

0.55

0.53

40

18.00

5.63

3.60

2.04

1.28

0.98

0.83

0.69

0.61

0.56

0.54

42

6.36

4.05

2.26

1.38

1.05

0.88

0.72

0.63

0.57

0.54

44

7.17

4.53

2.50

1.50

1.12

0.93

0.75

0.64

0.58

0.55

46

8.04

5.05

2.75

1.63

1.20

0.98

0.78

0.66

0.59

0.56

48

8.98

5.61

3.03

1.76

1.28

1.04

0.81

0.68

0.59

0.56

50

9.99

6.22

3.33

1.91

1.37

1.10

0.85

0.70

0.61

0.57

52

11.08

6.87

3.65

2.07

1.47

1.17

0.89

0.72

0.62

0.58

54

12.24

7.57

3.99

2.24

1.57

1.24

0.93

0.74

0.63

0.58

56

13.49

8.32

4.35

2.42

1.68

1.31

0.97

0.76

0.64

0.59

58

14.81

9.11

4.74

2.61

1.80

1.39

1.01

0.79

0.65

0.60

60

16.23

9.96

5.15

2.81

1.92

1.48

1.06

0.82

0.67

0.61

62

17.72

10.85

5.59

3.02

2.05

1.57

1.11

0.84

0.68

0.62

64

19.31

11.80

6.05

3.25

2.19

1.66

1.17

0.87

0.70

0.63

66

12.81

6.54

3.49

2.33

1.76

1.22

0.90

0.71

0.64

68

13.86

7.06

3.74

2.49

1.86

1.28

0.94

0.73

0.65

70

14.98

7.60

4.01

2.65

1.97

1.34

0.97

0.75

0.66

72

16.16

8.17

4.29

2.82

2.09

1.41

1.01

0.77

0.67

74

17.39

8.77

4.58

3.00

2.21

1.48

1.04

0.79

0.68

76

18.69

9.40

4.89

3.19

2.34

1.55

1.08

0.81

0.70

78

20.04

10.06

5.21

3.38

2.47

1.62

1.12

0.83

0.71

80

10.75

5.55

3.59

2.61

1.70

1.17

0.85

0.72

82

11.48

5.90

3.80

2.76

1.78

1.21

0.87

0.74

84

12.23

6.27

4.02

2.91

1.87

1.26

0.90

0.75

86

13.02

6.65

4.25

3.06

1.96

1.31

0.92

0.77

88

13.84

7.05

4.50

3.23

2.05

1.36

0.95

0.78

90

14.69

7.47

4.75

3.40

2.15

1.41

0.97

0.80

92

15.58

7.90

5.01

3.58

2.25

1.47

1.00

0.82

94

16.50

8.35

5.28

3.76

2.35

1.52

1.03

0.84

96

17.46

8.82

5.56

3.95

2.46

1.58

1.06

0.85

98

18.45

9.30

5.85

4.15

2.57

1.64

1.09

0.87

100

19.48

9.80

6.16

4.36

2.68

1.70

1.12

0.89

.50" Water Column have been Added To Static Pressure to Account for System Loss

Static Pressures are Calculated Using a 1.5 Factor Applied to Shedd's Data

GRAIN

DEPTH

FEET

Static Pressure (inches of water column)

Airflow Rate (cfm per bushel)