Pressure chart, Static pressure chart for clover – Grain Systems PNEG-501 User Manual

Page 20

Advertising
background image

20

Fan/Heater Application

PRESSURE CHART

STATIC PRESSURE CHART FOR CLOVER

3

2

1

3/4

1/2

1/3

1/4

1/5

1/7

1/10

1/15

1/20

2

1.50

1.16

0.83

0.74

0.66

0.61

0.58

0.56

0.55

0.53

0.52

0.52

4

4.63

3.19

1.82

1.48

1.15

0.93

0.82

0.76

0.68

0.63

0.59

0.56

6

10.09

6.69

3.50

2.73

1.97

1.47

1.23

1.08

0.92

0.79

0.69

0.64

8

18.06

11.75

5.89

4.49

3.13

2.24

1.80

1.54

1.24

1.02

0.84

0.76

10

18.44

9.01

6.79

4.64

3.23

2.54

2.13

1.66

1.31

1.04

0.90

12

12.89

9.64

6.49

4.45

3.44

2.85

2.17

1.67

1.28

1.08

14

17.54

13.04

8.70

5.89

4.52

3.70

2.78

2.09

1.56

1.29

16

17.02

11.27

7.57

5.77

4.69

3.48

2.58

1.88

1.53

18

14.21

9.48

7.18

5.82

4.28

3.13

2.25

1.81

20

17.52

11.63

8.78

7.08

5.17

3.75

2.66

2.12

22

14.02

10.54

8.48

6.17

4.44

3.12

2.46

24

16.64

12.49

10.02

7.25

5.20

3.62

2.83

26

19.52

14.61

11.70

8.44

6.02

4.16

3.24

28

16.91

13.52

9.72

6.91

4.75

3.68

30

19.39

15.48

11.11

7.87

5.38

4.15

32

17.58

12.59

8.89

6.06

4.66

34

19.83

14.17

9.98

6.78

5.19

36

15.85

11.14

7.55

5.77

38

17.63

12.37

8.36

6.37

40

19.51

13.67

9.21

7.01

42

15.04

10.11

7.68

44

16.47

11.06

8.39

46

17.98

12.05

9.12

48

19.56

13.09

9.90

50

14.17

10.70

52

15.29

11.54

54

16.47

12.41

56

17.68

13.32

58

18.95

14.26

60

20.26

15.23

62

16.24

64

17.28

66

18.36

68

19.47

70
72
74
76
78
80
82
84
86
88
90
92
94
96
98

100

.50" Water Column have been Added To Static Pressure to Account for System Loss

Static Pressures are Calculated Using a 1.5 Factor Applied to Shedd's Data

GRAIN

DEPTH

FEET

Static Pressure (inches of water column)

Airflow Rate (cfm per bushel)

Advertising