Fan/Heater Application

PLENUM TEMPERATURES

IMPORTANT!

DO NOT EXCEED

PLENUM

TEMPERATURES

LISTED IN TABLE

THIS TABLE IS NOT INTENDED AS A DRYING GUIDE.

IT SHOULD BE USED AS A REFERENCE FOR SETTING MAXIMUM PLENUM

TEMPERATURE FOR SAFE OPERATION.

LO-TEMP

BATCH

HIGH-

TEMP

BATCH DRY

NO STIRRING

HIGH-

TEMP
WITH

STIRRING

CONTINUOUS

FLOW

(RECIRCULATING)

CORN

5-20

0

ABOVE

AMBIENT

TEMP

120

0

140

0

160

0

RICE

5-10

0

ABOVE

AMBIENT

TEMP

100

0

100

0

NOT

RECOMMENDED

BEANS

&

WHEAT

5-20

0

ABOVE

AMBIENT

TEMP

110

0

120

0

NOT

RECOMMENDED