background image

14. Raising Bin

94

PNEG-1461 12', 15', 18' and 21' Bulk Feed Tank Series and Grain Hopper Tank Series

Bin Grounding Instructions

NOTE: Parts are not supplied by manufacturer. They should be purchased locally.

All bins shall have two (2) ground connections. Ground clamps must be placed at equal distances around
the bin.

Alternate Installation: Cables may be placed in the foundation or through PVC sleeve inserted in the slab
during construction.

Figure 14C

Ref #

Description

Ref #

Description

A

Cable Clamp

E

Number 2 Minimum (Typical)

B

5' (1524 mm) Copper Cable (Plain or Jacketed)

F

12" (305 mm)

C

Ground Rod Clamp

G

10'-0" Minimum (3048 mm)

D

Ground Rod 1/2" x 10' (3048 mm)

H

9'-0" Minimum (2743 mm)

NOTE:

Grounding rod must be placed

a minimum of 24" from concrete.