Service Platform & Stiffener

The Second and Third Module Stiffeners are as-
sembled the same way as the base module with only
minor variations. For the second module approxi-
mately 8.088" of stiffener should be left below the
frame of the module. Approximately 11.26" should
be left above the attach angle at the top. The splice
should be bolted as on the first module. For the third
module approximately 16.176" of stiffener should be
left below the frame of the module. Approximately
3.26" should be left above the attach angle at the top.
Splice the stiffener as before.

Splices should be used to connect the stiffeners as the
dryer modules are stacked. All bolts should be
checked and made tight to complete the installation.

SPECIAL BUTTRESS ASSEMBLY

Figure 35: Base module stiffener assembly.

Figure 36: Second module stiffener assembly.

Figure 37: Third module stiffener assembly.