3. Vision Control Panel

PNEG-1935 Vision Hybrid for Portable Dryers

15

Here, you will find the following options:

Speed Adjust buttons: These are used to adjust the setpoints if the Meter Roll Knob is disabled by
the software. For instructions on doing this, see

Operations Chapter on Page 21

.

Accept/Exit: To store the parameters and exit the screen.

Cancel/Exit: To disregard the changes and exit the screen.

Load Switch

This is used to select the operation of the fill auger. In both the AUTO and MANUAL positions, the load
auger will operate if the dryer is low on grain and will automatically shut OFF when the dryer is full. In the
AUTO position, the dryer will shutdown if the out of grain timer expires. The load delay is disabled
when the Load switch is in the MANUAL position. The switch will illuminate whenever the load auger
is operating.

Fan Switch

Each fan can be selected as ON, OFF or AUTO. The ON position operates the fan continuously during
staged batch and continuous flow modes. The AUTO position operates the fan in staged batch during the
dry and cool cycle, but the fan will turn OFF during the unload cycle. This switch will illuminate whenever
the Air Pressure switch, located in the proper plenum chamber, is sensing air pressure.

NOTE: The bottom fan on the dryer is always Fan one.

Heater Switch

Each heater can be selected as ON, OFF or AUTO with this switch. The AUTO position activates the
burner in staged batch during the dry cycle only. The ON position will activate the burner when the fan is
running and if air pressure is detected. The switch will illuminate only when the flame sensor detects
the flame.

NOTE: The bottom heater on the dryer is always Heater one.