6. Moisture Control Options

50

PNEG-1935 Vision Hybrid for Portable Dryers

Setup Procedure

1. Press the “Stop” button on the control panel if the dryer is running.

2. From the “Setup” screen, select “Drying Mode”, then “Staged Batch”.

3. From the “Drying Mode Selection” screen, select “M/C Setup” to access “Staged Batch Setup”.

4. Select “Moisture” from the “Staged Batch Drying Criteria”.

5. If desired, enable the “Max Grain Temp” safety.

6. Return to the “Default Operation Screen”.

7. Execute the equation above to determine the initial Dry Time value.

8. Set the Dry Timer, Cool Timer and Unload Timer to the desired time.

9. Press the “Temp” button.

10. Set the plenum setpoint to the preferred temperature(s).

11. Return to the “Default Operation Screen”.

12. Press the “M/C” button and set the desired moisture output.

13. Return to the “Default Operation Screen”.

14. Position “Unload” switch in the “AUTO” position.

15. Press the “Start” button on the control panel.