5. Operation

24

PNEG-1597 Sweep Tractor and Control Panel Assembly Instructions

(DI.LO) should be displayed on the unit.

Press

or

on the display unit until 0 is shown.

Press OK.

(DI.HI) should be displayed on the unit.

The DI.HI value will match the amperage range selection switch value on the current transducer
(30, 60 or 90). Refer part # AS-0736

on Page 39

.

Press

or

on the display unit until the correct value is shown.

Press OK repeatedly until “-----” is displayed. This indicates the programming described above has
been saved.

Make sure no individual is inside the bin.

Make sure the sweep will not contact any obstruction and cause damage.

Have an employee observe the sweep from outside the bin, through the open door.

Have another employee operate the control panel.

Switch the Run Mode switch so that Manual is selected (not Auto).

Switch the Manual Mode switch to idle (not reverse or forward).

Press the Start button on the control panel.

NOTE: If any damage is observed or there is abnormal operation of the sweep, shut it down immediately.

There are three (3) ways to accomplish this. 1) Remove the pressure on the safety foot switch.
2) Press the Stop button on the control panel. 3) Press in on the Enable/Disable button so that it
collapses appropriately. Switch the disconnect switch on the panel to OFF (not ON). Lock out the
panel before entering the bin to service the sweep.

Observe the no load amps (NLA) displayed on the meter on the front of the panel.

Auger drive motor no load amps: ____

The tractor motor operation (forward and stop) in automatic is dictated by the amp reading on the auger
drive motor.

The tractor drive motor is meant to shut off (idle) when the Auger Drive Motor reaches 90% of the
nameplate FLA.

90% of full load amps: ____

The tractor motor is meant to reactivate (forward) when the auger drive motor reaches 110% of the no load
amps (amperage observed when the auger flight turns freely in absence of grain).

110% of no load amps: ____