Vane axial fan pad – Grain Systems Tanks PNEG-1094 User Manual

Page 18

Advertising
background image

5. Foundations

18

PNEG-1094 Farm Grain Bin - 4" Corrugation

Placement of the Fan Pad: Transitions, Fans and Heaters Only

Vane Axial Fan Pad

If a fan or fan and heater combination is to be installed, refer to

Figure 5D

below, to determine the concrete

pad size.

1. The top of this pad should be level with the top of the bin’s foundation.

2. Recommended pad thickness is 4" minimum.

3. Front of pad should be perpendicular to bin wall.

4. Pad for heater is not required. If it is to be added, pour the pad to cover the locations of both the heater

and the fan.

For fans and transitions used in aeration duct system applications, refer to the transition and aeration
installation instructions.

Figure 5D Vane Axial Fan Pad

CAUTION

Fan pad and fan must be level and smooth for proper operation. Improper
leveling can cause vibration problems.

Advertising