Outside bin hold-down details (4.00" corrugation) – Grain Systems Tanks PNEG-1094 User Manual

Page 54

Advertising
background image

6. Installation

54

PNEG-1094 Farm Grain Bin - 4" Corrugation

Outside Bin Hold-Down Details (4.00" Corrugation)

Outside Hold-Downs

Outside bin hold-downs should be used on all non-stiffened bins. When anchoring the bin, be sure the
vertical seams of the bin align with the U-bolts in the foundation.

They may be anchored to the foundation using either the U-bolt and J-bolt combination or the single
anchor bolt, exception being 42' diameter and larger bins and bins 10 rings tall.

NOTE: All non-stiffened 42' and larger bins and bins 10 rings tall should use single anchor bolts, not the

U-bolt/J-bolt combination, 10 ring bins require double hold-downs. (Double U-bolt/J-bolt may be used
on non-stiffened 42' and larger bins no greater than 9 rings tall, as an option.)

Figure 6AA