R lp gas, Installation – Grain Systems PNEG-1702 User Manual
Page 19
4. Installation
PNEG-1702 ETL Listed GSI/FFI Portable Dryer Manual
19
Fuel System Specifications and Recommendations (LP) Liquid Propane
Dryer
Model #
Maximum Heat
Capacity BTU Per Hour
Maximum Fuel Flow
Gals Per Hour
Fuel Line Size*
Heater Orifice Drill Size
108/1108/190
3,500,000
38
1/2''
1/4''
112/1112/270
4,500,000
49
1/2''
21/64"
114/1114/320
5,750,000
63
1/2''
11/32"
116/1116/370
5,750,000
63
1/2''
11/32''
118/1118/400
7,000,000
76
1/2''
3/8"
120/1120/460
7,500,000
82
1/2''
25/64"
122/1122/511
8,500,000
93
3/4''
7/16"
126/1126/601
9,500,000
104
3/4''
29/64"
1214/2120
5,800,000
63
3/4''
(U)9/32" (L)7/32"
1216
6,800,000
74
3/4''
(U)21/64" (L)7/32"
1218/2125
6,800,000
74
3/4''
(U)21/64" (L)7/32"
1220/2130
8,750,000
96
3/4''
(U)11/32" (L)1/4"
1222
10,000,000
109
3/4''
(U)3/8" (L)1/4"
1226/2140
10,500,000
115
3/4''
(U)25/64" (L)1/4"
1214S/2141
7,000,000
76
3/4''
(2)-9/32"
1218S/2181
9,000,000
98
3/4''
(2)-21/64"
1220S/500H
11,500,000
126
3/4''
(2)-11/32"
1222S/2221
14,000,000
153
3/4''
(2)-3/8"
1226S/650M
15,000,000
164
3/4''
(2)-25/64"
2314/3142
11,750,000
128
3/4''
Top-11/32" Base (2)-1/4"
2318/3182
14,000,000
153
3/4''
Top-3/8" Base (2)-9/32"
2320/3202
16,500,000
180
3/4''
Top-25/64" Base (2)-21/64"
2322/3222
17,500,000
191
3/4''
Top-7/16" Base (2)-21/64"
2326/3262
24,500,000
267
3/4''
Top-29/64" Base (2)-23/64"
2420/1000H
18,000,000
197
3/4''
(4)-21/64"
2426/1300M
26,000,000
284
3/4''
(4)-23/64"
3414/4143
17,500,000
191
3/4''
Top-11/32" Mid-11/32" Base (2)-1/4"
3418/4183
21,000,000
229
3/4''
Top-3/8" Mid-3/8" Base (2)-9/32"
3420/4203
24,000,000
262
3/4''
Top-25/64" Mid-25/64" Base (2)-21/64"
3422/4223
26,000,000
284
3/4''
Top-7/16" Mid-7/16" Base (2)-21/64"
3426/4263
32,000,000
349
3/4''
Top-29/64" Mid-29/64" Base (2)-23/64"
3620/1500H
27,000,000
295
3/4''
(6)-21/64"
3626/2000M
39,000,000
426
3/4''
(6)-23/64"
* The minimum size of the fuel line for distances of 30.48 m (100').