11. Service

84

PNEG-1702 ETL Listed GSI/FFI Portable Dryer Manual

Lubrication Procedure

If the motors are equipped with an alemite fitting, clean the tip of the fitting and grease with a grease gun.
Use 1 or 2 full strokes on motors in NEMA 215 frame and smaller. Use 2 to 3 strokes on NEMA 254 through
NEMA 365 frame. Use 3 to 4 strokes on NEMA 404 frames and larger. On motors having drain plugs,
remove drain plugs and operate motor for 20 minutes before replacing drain plug. On motors equipped
with slotted head grease screw, remove screw and apply grease tube to hole. Insert 5 cm to 8 cm length
of grease string into each hole on motors in NEMA frame and smaller. Insert 8 cm to 13 cm length on larger
motors. On motors having grease drain plugs, remove plug and operate motor for 20 minutes before
replacing drain plug.

NOTE: All of the auger and metering roll bearings are lifetime lubricated and do not require

service lubrication.

Suggested Lubrication Schedules*

Suggested Lubricants

Hours of Service per Year

HP Range

Kw Range

Suggested Lube

Interval

5000

1/8 to 7-1/2

0.1 to 5.6

5 Years

10 to 40

7.5 to 29.8

3 Years

50 to 150

37.3 to 111.9

1 Year

Continuous Normal Applications

1/8 to 7-1/2

0.1 to 5.6

1 Year

10 to 40

7.5 to 29.8

3 Years

50 to 150

37.3 to 111.9

9 Years

Seasonal Service (Motor is idle for 6 months or more)

All

All

1 Year - beginning

of season

Continuous high ambient temperatures, dirty or moist

locations, high vibrations or when shaft gets hot

1/8 to 40

0.1 to 29.8

6 Months

50 to 150

37.3 to 111.9

3 Months

* The bearings have been lubricated at the factory, thus no lubrication should be added before start-up.

Insulation Class

Consistency

Type

Grease

Frame Type

A and B

Medium

Polyurea

Shell Dolium R

215T and Smaller

A and B

Medium

Polyurea

Shell Dolium R

254 and Larger

F and H

Medium

Polyurea

Shell Dolium R

All